Literature DB >> 14616252

Screening for congenital malformations by ultrasonography in the general population of pregnant women: factors affecting the efficacy.

Ann Tabor1, Milica Zdravkovic, Annette Perslev, Lars Krag Møller, Beth Lilja Pedersen.   

Abstract

OBJECTIVES: To assess whether the efficacy of screening for fetal malformations is affected by patient-, staff-, team- or work environment-related factors.
METHODS: A prospective cohort study was carried out at a Danish university hospital with 4000 deliveries per year. In total, 7963 fetuses were examined by midtrimester ultrasound scan during 1997 and 1998. The infants were followed up to the age of at least 1 year. The main outcome measures were the detection rate (DR) of fetal abnormalities in relation to patient factors, staff factors, team and work environment factors.
RESULTS: Significant malformations were detected in 100 fetuses or infants, corresponding to an incidence of 1.3%. The prenatal DR was 60%. High maternal body mass index (BMI) was associated with a lower DR, while the presence of twins, the gestational age at time of screening and the sonographer's level of experience were not. Fetuses with a prenatally undetected malformation were more often examined by more than one sonographer than fetuses without congenital malformations. Workload or monotony did not seem to affect the efficacy of screening. There was a trend towards a lower detection rate at midday and when most of the staff were at work.
CONCLUSIONS: Some team and work environment factors that may affect the detection rate of fetal abnormalities were identified and have been changed: appointments for screening have been reorganized, regular breaks for all the staff introduced and second opinions are given by a specialist in fetomaternal medicine. The new system will be followed up to ensure that the reorganization has not created new organizational mistakes.

Entities:  

Mesh:

Year:  2003        PMID: 14616252     DOI: 10.1046/j.1600-0412.2003.00238.x

Source DB:  PubMed          Journal:  Acta Obstet Gynecol Scand        ISSN: 0001-6349            Impact factor:   3.636


  2 in total

1.  The Performance of First-Trimester Anatomy Scan: A Decision Analysis.

Authors:  Lorie M Harper; S Lindsay Wood; Sheri M Jenkins; John Owen; Joseph R Biggio
Journal:  Am J Perinatol       Date:  2016-04-22       Impact factor: 1.862

2.  Correlation between ultrasound diagnosis and autopsy findings of fetal malformations.

Authors:  Antonella Vimercati; Silvana Grasso; Marinella Abruzzese; Annarosa Chincoli; Alessandra de Gennaro; Angela Miccolis; Gabriella Serio; Luigi Selvaggi; Fabiana Divina Fascilla
Journal:  J Prenat Med       Date:  2012-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.