Literature DB >> 14613255

In vivo behavior of poly(1,3-trimethylene carbonate) and copolymers of 1,3-trimethylene carbonate with D,L-lactide or epsilon-caprolactone: Degradation and tissue response.

A P Pêgo1, M J A Van Luyn, L A Brouwer, P B van Wachem, A A Poot, D W Grijpma, J Feijen.   

Abstract

The degradation and the tissue response evoked by poly(1,3-trimethylene carbonate) [poly(TMC)] and copolymers of TMC with either 52 mol % D,L-lactide (DLLA) or 89 mol % epsilon-caprolactone (CL) were evaluated in vivo by subcutaneous implantation of polymer films in rats for periods up to one year. Poly(TMC) specimens were extensively degraded after 3 weeks and, as confirmed by histology, totally resorbed in less than a year. A fast linear decrease in thickness and mass without a change in molecular weight was observed. Initially an acute sterile inflammatory tissue reaction, caused by the implantation procedure, was observed, followed by a mild macrophage-mediated foreign body reaction that lasted during the resorption period of the polymer. It is concluded that in vivo, poly(TMC) is degraded via surface erosion involving cellular-mediated processes. The degradation of the copolymers was slower than that of poly(TMC), taking place via autocatalyzed bulk hydrolysis, preferentially of ester bonds. The TMC-DLLA copolymer degraded 20 times faster than the TMC-CL one. In both cases, the tissue reaction upon implantation resembled a sterile inflammatory reaction followed by a foreign body reaction that led to the polymer encapsulation. Significant mass loss was only observed for the TMC-DLLA copolymer, which underwent 96% mass loss in 1 year. When extensive mass loss started, a mild-to-moderate secondary foreign body reaction, related to clearance of the polymer fragments, was triggered. The results presented in this study demonstrate that poly(TMC) and both TMC copolymers are biodegradable and biocompatible materials, making these polymers attractive for the preparation of short- and long-term degradable devices for soft tissue engineering. Copyright 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1044-1054, 2003

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14613255     DOI: 10.1002/jbm.a.10121

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  26 in total

Review 1.  Bioactive polymer scaffold for fabrication of vascularized engineering tissue.

Authors:  Irza Sukmana
Journal:  J Artif Organs       Date:  2012-04-21       Impact factor: 1.731

Review 2.  Degradable Controlled-Release Polymers and Polymeric Nanoparticles: Mechanisms of Controlling Drug Release.

Authors:  Nazila Kamaly; Basit Yameen; Jun Wu; Omid C Farokhzad
Journal:  Chem Rev       Date:  2016-02-08       Impact factor: 60.622

3.  Biodegradable polyurethane ureas with variable polyester or polycarbonate soft segments: effects of crystallinity, molecular weight, and composition on mechanical properties.

Authors:  Zuwei Ma; Yi Hong; Devin M Nelson; Joseph E Pichamuthu; Cory E Leeson; William R Wagner
Journal:  Biomacromolecules       Date:  2011-07-26       Impact factor: 6.988

4.  Will the hold of solid biodegradable implants be influenced by swelling during the degradation process? An in-vitro study with Meniscus Arrows.

Authors:  Diederick B Wouters; Rudolf R M Bos; Jeff T De Hosson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-06-23       Impact factor: 4.342

5.  Elastomeric electrospun scaffolds of poly(L-lactide-co-trimethylene carbonate) for myocardial tissue engineering.

Authors:  Shayanti Mukherjee; Chiara Gualandi; Maria Letizia Focarete; Rajeswari Ravichandran; Jayarama Reddy Venugopal; Michael Raghunath; Seeram Ramakrishna
Journal:  J Mater Sci Mater Med       Date:  2011-05-27       Impact factor: 3.896

6.  Biomedical Applications of Biodegradable Polymers.

Authors:  Bret D Ulery; Lakshmi S Nair; Cato T Laurencin
Journal:  J Polym Sci B Polym Phys       Date:  2011-06-15

7.  Osteoblast behaviour on in situ photopolymerizable three-dimensional scaffolds based on D, L-lactide, epsilon-caprolactone and trimethylene carbonate.

Authors:  H A Declercq; M J Cornelissen; T L Gorskiy; E H Schacht
Journal:  J Mater Sci Mater Med       Date:  2006-02       Impact factor: 3.896

8.  Creep-resistant porous structures based on stereo-complex forming triblock copolymers of 1,3-trimethylene carbonate and lactides.

Authors:  Zheng Zhang; Dirk W Grijpma; Jan Feijen
Journal:  J Mater Sci Mater Med       Date:  2004-04       Impact factor: 3.896

Review 9.  Recent advances in synthetic bioelastomers.

Authors:  Rui Shi; Dafu Chen; Quanyong Liu; Yan Wu; Xiaochuan Xu; Liqun Zhang; Wei Tian
Journal:  Int J Mol Sci       Date:  2009-11-20       Impact factor: 6.208

10.  A biodegradable antibiotic delivery system based on poly-(trimethylene carbonate) for the treatment of osteomyelitis.

Authors:  Daniëlle Neut; Otto S Kluin; Bart J Crielaard; Henny C van der Mei; Henk J Busscher; Dirk W Grijpma
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.