Literature DB >> 14605718

[Distal radius fractures. 2.4 mm locking compression plates. Are they worth the effort?].

A Schupp1, C Tuttlies, T Möhlig, H R Siebert.   

Abstract

Fracture of the distal radius has a second peak of incidence in the second half of life. Because complex injuries are seen frequently, there is a need for differentiated treatment to achieve good results. The aim of our study was to evaluate the treatment of distal radius fractures with 2.4-mm locking compression (LC) plates in patients older than 65 years suffering from osteoporosis to determine the complications and compare costs of treatment with different interventions. Thirty-seven patients were included in this prospective study. The distribution of fractures according to AO classification was: nine type A, one type B, and 27 type C. The mean age was 76 years. Twenty-six volar plates, seven dorsal and four "sandwich" procedures were applied. The mean follow-up for 33 patients was 11.1 months. Using the functional Lidström score, we found 13 very good results, 15 good, four fair, and one poor, the radiologic Lidström scores were: 15 very good, 13 good, four fair, and one poor results. With the application of 2.4-mm LC plates, findings were good or very good in over 80%of osteoporotic distal radial fractures. Compared to other treatments, the real costs of intervention for LC plates is much higher.

Entities:  

Mesh:

Year:  2003        PMID: 14605718     DOI: 10.1007/s00104-003-0765-9

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  29 in total

1.  Grip test; the use of a dynamometer with adjustable handle spacings.

Authors:  C O BECHTOL
Journal:  J Bone Joint Surg Am       Date:  1954-07       Impact factor: 5.284

2.  [Direct cost assessment of wrist fractures].

Authors:  B Chamberlin; J P Benazet; B Humbert; G Saillant
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1999-12

3.  The radio-radial external fixator in the treatment of fractures of the distal radius.

Authors:  T Fischer; P Koch; C Saager; G N Kohut
Journal:  J Hand Surg Br       Date:  1999-10

4.  Intra-articular fractures of the distal part of the radius treated with the small AO external fixator.

Authors:  G S Edwards
Journal:  J Bone Joint Surg Am       Date:  1991-09       Impact factor: 5.284

5.  Injectable calcium phosphate in the treatment of distal radial fractures.

Authors:  P Kopylov; K Jonsson; K G Thorngren; P Aspenberg
Journal:  J Hand Surg Br       Date:  1996-12

6.  [Is the static external fixator a suitable method in the treatment of multi-fragmented fractures of the distal radius?].

Authors:  P Povacz; H Breitfuss; H Klampfer
Journal:  Handchir Mikrochir Plast Chir       Date:  1996-11       Impact factor: 1.018

7.  Triangular fibrocartilage disorders: injury patterns and treatment.

Authors:  A K Palmer
Journal:  Arthroscopy       Date:  1990       Impact factor: 4.772

8.  The amount of bone in the metacarpal and the phalanx according to age and sex.

Authors:  D B Morgan; F W Spiers; C N Pulvertaft; P Fourman
Journal:  Clin Radiol       Date:  1967-01       Impact factor: 2.350

Review 9.  [Accident mechanisms and classification in distal radius fracture].

Authors:  D Havemann; F W Busse
Journal:  Langenbecks Arch Chir Suppl II Verh Dtsch Ges Chir       Date:  1990

10.  Osteoporosis and Colles' fractures in the elderly.

Authors:  J J Dias; C C Wray; J M Jones
Journal:  J Hand Surg Br       Date:  1987-02
View more
  10 in total

Review 1.  [Fracture of the distal radius].

Authors:  H R Siebert; A Klonz
Journal:  Unfallchirurg       Date:  2005-02       Impact factor: 1.000

2.  Females Are Not Proportionally Smaller Males: Relationships Between Radius Anthropometrics and Their Sex Differences.

Authors:  Mitchell L Thom; Katherine Willmore; Alexandra Surugiu; Emily Lalone; Timothy A Burkhart
Journal:  Hand (N Y)       Date:  2019-02-28

3.  [Is use of the fixateur externe no longer indicated for the treatment of unstable radial fracture in the elderly?].

Authors:  S Ochman; U Frerichmann; N Armsen; M J Raschke; R H Meffert
Journal:  Unfallchirurg       Date:  2006-12       Impact factor: 1.000

4.  [Volar locking plating for distal radial fractures. Is osteoporosis associated with poorer functional results and higher complications rates?].

Authors:  C Voigt; A Plesz; G Jensen; C Katthagen; H Lill
Journal:  Chirurg       Date:  2012-05       Impact factor: 0.955

5.  [Early results after palmar multi-axial plate osteosynthesis for treatment of distal radius fractures].

Authors:  T Geyer; K Hefele; J Gülke; F Gebhard; M Mentzel
Journal:  Unfallchirurg       Date:  2011-10       Impact factor: 1.000

Review 6.  [Trauma surgery in the elderly].

Authors:  H R Siebert; A Beck
Journal:  Chirurg       Date:  2005-02       Impact factor: 0.955

7.  [What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly?].

Authors:  C Voigt; H Lill
Journal:  Unfallchirurg       Date:  2006-10       Impact factor: 1.000

8.  [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

Authors:  M Hakimi; P Jungbluth; S Gehrmann; J Nowak; J Windolf; M Wild
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

9.  [Quality of care after distal radius fracture in Germany. Results of a fracture register of 1,201 elderly patients].

Authors:  R Smektala; H G Endres; B Dasch; F Bonnaire; H J Trampisch; L Pientka
Journal:  Unfallchirurg       Date:  2009-01       Impact factor: 1.000

10.  [Do fixed-angle T-plates offer advantages for distal radius fractures in elderly patients?].

Authors:  M Walz; B Kolbow; F Auerbach
Journal:  Unfallchirurg       Date:  2004-08       Impact factor: 1.000

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.