Literature DB >> 17043789

[Is use of the fixateur externe no longer indicated for the treatment of unstable radial fracture in the elderly?].

S Ochman1, U Frerichmann, N Armsen, M J Raschke, R H Meffert.   

Abstract

BACKGROUND: In recent years there has been an increasingly marked shift in the operative treatment of unstable fractures of the distal radius. The introduction of locking compression plates has made it possible to extend the indications for palmar stabilisation according to the principles of internal fixation to extension fractures even in osteoporotic bone, and since then the new design has been used more and more widely. First clinical results show very good and good clinical and radiological outcomes in over 80% of cases after locking compression plate osteosynthesis. All this raises the question of whether external fixation is no longer indicated for distal radius fractures in the elderly, or is now no more than a second-line treatment. PATIENTS AND METHODS: Within a 5-year period, 67 patients over 65 years of age were identified among 220 who had had unstable fractures of the distal radius in our hospital with external fixation. The average follow-up period (clinical and radiological examinations) was 37 months. We devoted particular attention to the analysis of complications and problems during the treatment.
RESULTS: Complete bone healing was observed in all patients treated with external fixation. In most cases, complications were minor pin-track infections (10%). The radiological follow-up examination revealed radial shortening by an average of 2 mm and an average radial shift of 0.2 mm. The joint angle was 2.5 degrees with lateral irradiation and 18 degrees with dorso-palmar irradiation. According to the Gartland and Werley score, the functional, radiological and subjective outcome was excellent or good in 87% of these patients.
CONCLUSIONS: Overall, internal fixation with angular fixed plates has definite benefits. The medium- and long-term follow-up and functional outcome still show no benefits over external fixation, however. External fixation is a genuine option, even if as second-line treatment.

Entities:  

Mesh:

Year:  2006        PMID: 17043789     DOI: 10.1007/s00113-006-1166-6

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  32 in total

1.  Reduction techniques in distal radius fractures.

Authors:  W Dée; W Klein; H Rieger
Journal:  Injury       Date:  2000       Impact factor: 2.586

2.  Minor axial shortening of the radius affects outcome of Colles' fracture treatment.

Authors:  H T Aro; T Koivunen
Journal:  J Hand Surg Am       Date:  1991-05       Impact factor: 2.230

3.  Evaluation of healed Colles' fractures.

Authors:  J J GARTLAND; C W WERLEY
Journal:  J Bone Joint Surg Am       Date:  1951-10       Impact factor: 5.284

4.  [Fractures of the distal forearm. Which therapy is indicated when?].

Authors:  E Brug; U Joosten; M Püllen
Journal:  Orthopade       Date:  2000-04       Impact factor: 1.087

5.  External fixation for unstable intra-articular distal radial fractures in women older than 55 years. Acceptable functional end results in the majority of the patients despite significant secondary displacement.

Authors:  J H Hegeman; J Oskam; P A M Vierhout; H J Ten Duis
Journal:  Injury       Date:  2005-02       Impact factor: 2.586

6.  Unstable Colles' fractures in elderly patients. A randomised trial of external fixation for redisplacement.

Authors:  R M Roumen; W L Hesp; E D Bruggink
Journal:  J Bone Joint Surg Br       Date:  1991-03

7.  A model of lifetime osteoporosis impact.

Authors:  E A Chrischilles; C D Butler; C S Davis; R B Wallace
Journal:  Arch Intern Med       Date:  1991-10

8.  [Palmar fixed angle plating systems for instable distal radius fractures].

Authors:  H Krimmer; C Pessenlehner; K Hasselbacher; M Meier; F Roth; R Meier
Journal:  Unfallchirurg       Date:  2004-06       Impact factor: 1.000

9.  Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

10.  Fracture of the distal radius: classification of treatment and indications for external fixation.

Authors:  S Graff; J Jupiter
Journal:  Injury       Date:  1994       Impact factor: 2.586

View more
  6 in total

1.  Radiological dorsal tilt analysis of AO type A, B, and C fractures of the distal radius treated conservatively or with extra-focal K-wire plus external fixateur.

Authors:  Michael Hoffmann; Malte Schroeder; Kai Kossow; Michaela Gruber-Rathmann; Andreas H Ruecker
Journal:  Skeletal Radiol       Date:  2012-02-05       Impact factor: 2.199

2.  Can the displacement of a conservatively treated distal radius fracture be predicted at the beginning of treatment?

Authors:  T Einsiedel; W Freund; S Sander; S Trnavac; F Gebhard; M Kramer
Journal:  Int Orthop       Date:  2008-05-27       Impact factor: 3.075

Review 3.  [Osteoporotic fractures of the distal radius. What is new?].

Authors:  J Meiners; C Jürgens; S Mägerlein; S Wallstabe; B Kienast; M Faschingbauer
Journal:  Chirurg       Date:  2012-10       Impact factor: 0.955

Review 4.  A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly.

Authors:  Rafael J Diaz-Garcia; Takashi Oda; Melissa J Shauver; Kevin C Chung
Journal:  J Hand Surg Am       Date:  2011-05       Impact factor: 2.230

5.  External fixation of fractures of the distal radius: a randomized comparison of the Hoffman compact II non-bridging fixator and the Dynawrist fixator in 75 patients followed for 1 year.

Authors:  Yngvar Krukhaug; Stein Ugland; Stein A Lie; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

6.  DISTAL RADIAL FRACTURES IN PATIENTS OVER 60 YEARS OLD: ORTHOGONAL PLATES VERSUS VOLAR PLATE.

Authors:  Edgard Novaes de França Bisneto; Emygdio José Leomil de Paula; Marcelo Rosa de Resende; Rames Mattar Júnior; Arnaldo Valdir Zumiotti
Journal:  Rev Bras Ortop       Date:  2015-11-16
  6 in total