Literature DB >> 14604242

Heparin monitoring during cardiac surgery. Part 1: Validation of whole-blood heparin concentration and activated clotting time.

P D Raymond1, M J Ray, S N Callen, N A Marsh.   

Abstract

There is limited published data on the agreement between techniques for monitoring heparin levels. The aim of this study was to validate the Hepcon/HMS, with particular focus on the agreement with laboratory anti-Xa assay. The performances of two ACT instruments--Hemochron and HemoTec--were also evaluated, including an assessment for interchangeability. Blood samples from 42 adult cardiopulmonary bypass (CPB) patients were analysed for activated clotting time (ACT), whole-blood heparin concentration (Hepcon/HMS) and anti-factor Xa (anti-Xa) plasma heparin concentration. Agreement between measures was determined using the method of Bland and Altman. Simple analysis of agreement between the Hepcon and anti-Xa heparin revealed the Hepcon has a mean bias of -0.46 U/mL, with the limits of agreement +/- 1.12 U/mL. The comparison between ACT instruments indicated a mean difference of -96 seconds for the HemoTec, with limits of +/- 265 seconds. The Hepcon/ HMS instrument displayed satisfactory agreement with anti-Xa plasma heparin concentration, as the expected variation would not be expected to cause problems in the clinical setting. Agreement between the two measurements of ACT may be satisfactory, provided each is assigned a different target value.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14604242     DOI: 10.1191/0267659103pf672oa

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  11 in total

1.  A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy.

Authors:  C R Krebs; Ling Li; Alisa S Wolberg; Amy L Oldenburg
Journal:  Rev Sci Instrum       Date:  2015-07       Impact factor: 1.523

2.  Heparin monitoring during cardiopulmonary bypass surgery using the one-step point-of-care whole blood anti-factor-Xa clotting assay heptest-POC-Hi.

Authors:  Peter Hellstern; Juergen Bach; Melanie Simon; Werner Saggau
Journal:  J Extra Corpor Technol       Date:  2007-06

3.  Blood and Blood Product Conservation: Results of Strategies to Improve Clinical Outcomes in Open Heart Surgery Patients at a Tertiary Hospital.

Authors:  Junaid H Khan; Emily A Green; Jimmin Chang; Alexandria M Ayala; Marilyn S Barkin; Emily E Reinys; Jeffrey Stanton; Russell D Stanten
Journal:  J Extra Corpor Technol       Date:  2017-12

4.  Monitoring of heparin and its low-molecular-weight analogs by silicon field effect.

Authors:  Nebojsa M Milovic; Jonathan R Behr; Michel Godin; Chih-Sheng Johnson Hou; Kristofor R Payer; Aarthi Chandrasekaran; Peter R Russo; Ram Sasisekharan; Scott R Manalis
Journal:  Proc Natl Acad Sci U S A       Date:  2006-08-28       Impact factor: 11.205

Review 5.  Are We Able to Dose Protamine Accurately Yet? A Review of the Protamine Conundrum.

Authors:  Patrick Hecht; Martin Besser; Florian Falter
Journal:  J Extra Corpor Technol       Date:  2020-03

6.  In vitro and in vivo effects of hemodilution on kaolin-based activated clotting time predicted heparin requirement using a heparin dose-response technique.

Authors:  Junko Ichikawa; Satoshi Hagihira; Testu Mori; Mitsuharu Kodaka; Keiko Nishiyama; Makoto Ozaki; Makiko Komori
Journal:  J Anesth       Date:  2016-08-08       Impact factor: 2.078

7.  Heparin concentration-based anticoagulation for cardiac surgery fails to reliably predict heparin bolus dose requirements.

Authors:  Sean Garvin; Daniel C FitzGerald; George Despotis; Prem Shekar; Simon C Body
Journal:  Anesth Analg       Date:  2009-10-27       Impact factor: 5.108

8.  A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Authors:  Si-Si Liang; Xu Deng; Yao-Yao Fan; Jun Li; Man Wang; Zhi-Qi Zhang
Journal:  Mikrochim Acta       Date:  2018-10-25       Impact factor: 5.833

9.  A rolling circle amplification based platform for ultrasensitive detection of heparin.

Authors:  Lei Lin; Bingzhi Li; Xiaorui Han; Fuming Zhang; Xing Zhang; Robert J Linhardt
Journal:  Analyst       Date:  2020-11-23       Impact factor: 4.616

10.  Time course of haemostatic effects of fibrinogen concentrate administration in aortic surgery.

Authors:  C Solomon; C Hagl; N Rahe-Meyer
Journal:  Br J Anaesth       Date:  2013-02-06       Impact factor: 9.166

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.