CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate.

Patricia R Geraghty1, Stephen T Kee, Gillian McFarlane, Mahmood K Razavi, Daniel Y Sze, Michael D Dake.   

Abstract

PURPOSE: To evaluate the effect of coaxial needle size on pneumothorax rate and the diagnostic accuracy of computed tomography (CT)-guided transthoracic needle aspiration biopsy (TNAB) of pulmonary nodules.
MATERIALS AND METHODS: Retrospective review of 846 consecutive CT-guided TNAB procedures was performed. A coaxial approach was implemented in all patients by using an 18- or 19-gauge outer stabilizing needle through which a smaller aspiration needle or automated biopsy gun was inserted for tissue sampling. Univariate and multivariate regression analyses were used to analyze coaxial needle size, age, sex, smoking history, lesion size, use of an automated core biopsy gun, number of needle passes, and frequency of chest tube placement. Sensitivity, specificity, and diagnostic accuracy were calculated for 676 patients with at least 18 months of clinical follow-up.
RESULTS: Pneumothorax occurred in 226 of 846 patients. Coaxial needle size and patient age had a significant effect on pneumothorax rate. Pneumothorax occurred in 124 (38%) of 324 patients who underwent procedures with 18-gauge needles and in 121 (23%) of 522 patients who underwent procedures with 19-gauge needles (P <.001). The overall diagnostic accuracy was 96% for procedures performed with 18-gauge needles and 92% for procedures performed with 19-gauge needles, with a sensitivity of 95% and 89% and a specificity of 100% and 99%, respectively. Pneumothorax occurred in 153 patients older than 60 years, in 99 patients 60 years and younger (P <.02), in 90 patients older than 70 years, and in 162 patients younger than 70 years (P <.01). The relationship between pneumothorax rate and age as a continuous distribution was not significant (P <.07), nor were the 50- or 75-year age cutoffs (P <.06 and P <.9, respectively).
CONCLUSION: Use of a smaller coaxial stabilizing needle produces a substantially decreased risk of pneumothorax with comparable diagnostic accuracy, sensitivity, and specificity for histopathologic diagnosis of pulmonary nodules. Copyright RSNA, 2003

Entities:  

Mesh:

Year:  2003        PMID: 14595149     DOI: 10.1148/radiol.2291020499

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  108 in total

1.  Transthoracic needle biopsy.

Authors:  Katherine R Birchard
Journal:  Semin Intervent Radiol       Date:  2011-03       Impact factor: 1.513

2.  Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.

Authors:  Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

3.  Value of high-resolution ultrasound in detecting a pneumothorax.

Authors:  Myung Jin Chung; Jin Mo Goo; Jung-Gi Im; Jae Min Cho; Sung Bum Cho; Seog Joon Kim
Journal:  Eur Radiol       Date:  2004-12-18       Impact factor: 5.315

4.  Electromagnetic navigation diagnostic bronchoscopy: a prospective study.

Authors:  Thomas R Gildea; Peter J Mazzone; Demet Karnak; Moulay Meziane; Atul C Mehta
Journal:  Am J Respir Crit Care Med       Date:  2006-07-27       Impact factor: 21.405

5.  Pulmonary thermal ablation: comparison of radiofrequency and microwave devices by using gross pathologic and CT findings in a swine model.

Authors:  Christopher L Brace; J Louis Hinshaw; Paul F Laeseke; Lisa A Sampson; Fred T Lee
Journal:  Radiology       Date:  2009-03-31       Impact factor: 11.105

6.  Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records.

Authors:  Renda Soylemez Wiener; Lisa M Schwartz; Steven Woloshin; H Gilbert Welch
Journal:  Ann Intern Med       Date:  2011-08-02       Impact factor: 25.391

7.  [Image-guided biopsy of the thorax].

Authors:  C Stroszczynski; A Jöres; J von Ruthendorf-Przewoski; A Bethke
Journal:  Radiologe       Date:  2008-12       Impact factor: 0.635

8.  Pneumothorax: a common complication of CT-guided transthoracic needle lung biopsy.

Authors:  Subhash Chandra; Dipti Agarwal; Vikash Singh; Anant Mohan; Randeep Guleria
Journal:  BMJ Case Rep       Date:  2009-05-08

9.  Dual-slot antennas for microwave tissue heating: parametric design analysis and experimental validation.

Authors:  Christopher L Brace
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

10.  Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety.

Authors:  M J Choi; Y Kim; Y S Hong; S S Shim; S M Lim; J K Lee
Journal:  Br J Radiol       Date:  2011-07-26       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.