Literature DB >> 14585479

KLM model for lossy piezoelectric transducers.

Martha Castillo1, Pedro Acevedo, Eduardo Moreno.   

Abstract

A KLM model has been developed using equivalent circuits to analyze the effects of different loss mechanisms on the transducer performance in the time and frequency domain. Transducers from two different piezoelectric materials (lead-zirconate-titanate (PZT) and polyvinylidene fluoride) were constructed to validate our model. Experimental results are in good agreement with the theoretical simulation.

Entities:  

Mesh:

Year:  2003        PMID: 14585479     DOI: 10.1016/s0041-624x(03)00101-x

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  6 in total

1.  Physical principles for scalable neural recording.

Authors:  Adam H Marblestone; Bradley M Zamft; Yael G Maguire; Mikhail G Shapiro; Thaddeus R Cybulski; Joshua I Glaser; Dario Amodei; P Benjamin Stranges; Reza Kalhor; David A Dalrymple; Dongjin Seo; Elad Alon; Michel M Maharbiz; Jose M Carmena; Jan M Rabaey; Edward S Boyden; George M Church; Konrad P Kording
Journal:  Front Comput Neurosci       Date:  2013-10-21       Impact factor: 2.380

2.  Pb(Mg1/3Nb2/3)-PbTiO3-Based Ultrasonic Transducer for Detecting Infiltrated Water in Pressurized Water Reactor Fuel Rods.

Authors:  Geonwoo Kim; Nam-Kyoung Choi; Yong-Il Kim; Ki-Bok Kim
Journal:  Sensors (Basel)       Date:  2019-06-13       Impact factor: 3.576

3.  Application of Adaptive Wave Cancellation Underwater to a Piezoelectric-Material-Based Multilayer Sensor.

Authors:  Hyodong Lee; Hwijin Park; Kwankyu Park; Hak Yi
Journal:  Sensors (Basel)       Date:  2019-12-24       Impact factor: 3.576

Review 4.  Recent Development and Perspectives of Optimization Design Methods for Piezoelectric Ultrasonic Transducers.

Authors:  Dongdong Chen; Linwei Wang; Xingjun Luo; Chunlong Fei; Di Li; Guangbao Shan; Yintang Yang
Journal:  Micromachines (Basel)       Date:  2021-06-30       Impact factor: 2.891

5.  Performance Enhancement of an Ultrasonic Power Transfer System Through a Tightly Coupled Solid Media Using a KLM Model.

Authors:  Bibhu Kar; Ulrike Wallrabe
Journal:  Micromachines (Basel)       Date:  2020-03-30       Impact factor: 2.891

6.  Comparison between Resonance and Non-Resonance Type Piezoelectric Acoustic Absorbers.

Authors:  Joo Young Pyun; Young Hun Kim; Soo Won Kwon; Won Young Choi; Kwan Kyu Park
Journal:  Sensors (Basel)       Date:  2019-12-20       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.