Literature DB >> 14581401

Feasibility and safety of pulmonary vein isolation using a new mapping and navigation system in patients with refractory atrial fibrillation.

Thomas Arentz1, Jörg von Rosenthal, Thomas Blum, Jochem Stockinger, Gerd Bürkle, Reinhold Weber, Nikolaus Jander, Franz Josef Neumann, Dietrich Kalusche.   

Abstract

BACKGROUND: Ostial pulmonary vein (PV) isolation by radiofrequency (RF) catheter ablation can cure patients with atrial fibrillation (AF); however, this procedure carries the risk of PV stenosis. The aim of this study was to assess the feasibility of a new mapping and navigation technique using a multipolar basket catheter (BC) for PV isolation in patients with refractory AF and to analyze its safety with regard to PV stenosis at long-term follow-up. METHODS AND
RESULTS: We studied 55 patients (mean age, 53+/-11 years; 40 male) with drug-refractory AF (paroxysmal, n=37; persistent, n=18). A 64-pole BC was placed transseptally into each of the accessible PVs. By use of a nonfluoroscopic navigation system, the ablation catheter was guided to the BC electrodes at the PV ostium, with earliest activation during sinus rhythm. RF was delivered by use of maximum settings of temperature at 50 degrees C and power at 30 W. The end point of the procedure was the complete elimination of all distal and fragmented ostial PV potentials. Of 165 targeted veins, 163 were successfully isolated with a mean RF duration of 720+/-301 seconds per vein. At 1-year follow-up, 62% of the patients were in sinus rhythm without antiarrhythmic drugs. Contrast-enhanced magnetic resonance angiography revealed 2 PV stenoses of >25% out of 165 treated vessels.
CONCLUSIONS: The use of a multipolar BC allowed effective and safe PV isolation by combining 3D mapping and navigation. At 1-year follow-up, 62% of the patients were in sinus rhythm without antiarrhythmic drugs, and the incidence of relevant diameter reduction of the treated PVs was 1.2%.

Entities:  

Mesh:

Year:  2003        PMID: 14581401     DOI: 10.1161/01.CIR.0000097118.75179.83

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  26 in total

1.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  Circulation       Date:  2010-05-17       Impact factor: 29.690

Review 2.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  J Am Coll Cardiol       Date:  2010-06-08       Impact factor: 24.094

Review 3.  Evaluating the left atrium by magnetic resonance imaging.

Authors:  Thomas H Hauser; Dana C Peters; John V Wylie; Warren J Manning
Journal:  Europace       Date:  2008-11       Impact factor: 5.214

4.  Visualization of multiple catheters in left atrial ablation procedures. Comparison of two different 3D mapping systems.

Authors:  C Jilek; G Hessling; S Ammar; S Fichtner; T Reents; H L Estner; J Wu; C Kolb; I Deisenhofer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-03

5.  Acute and long-term results of PVI at antrum using a novel high-density mapping catheter without help of 3D electro-anatomic mapping in patients with paroxysmal and chronic atrial fibrillation.

Authors:  Thomas Neumann; Malte Kuniss; Damir Erkapic; Sergey Zaltsberg; Alexander Berkowitsch; Dimitri Pajitnev; Maciej Wojcik; Sebastien Janin; Christian W Hamm; Heinz F Pitschner
Journal:  J Interv Card Electrophysiol       Date:  2010-01-20       Impact factor: 1.900

Review 6.  Advanced mapping techniques in atrial fibrillation.

Authors:  Lars Lickfett; Jörg O Schwab; Thorsten Lewalter
Journal:  J Interv Card Electrophysiol       Date:  2008-04-02       Impact factor: 1.900

7.  Anatomic guidance for ablation: atrial flutter, fibrillation, and outflow tract ventricular tachycardia.

Authors:  Nandini Sehar; Jennifer Mears; Susan Bisco; Sandeep Patel; Nirusha Lachman; Samuel J Asirvatham
Journal:  Indian Pacing Electrophysiol J       Date:  2010-08-10

8.  Advanced electrophysiologic mapping systems: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-03-01

9.  Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results.

Authors:  Marcus Wieczorek; Reinhard Hoeltgen; Martin Brueck; Dirk Bandorski; Elvan Akin; Ali Reza Salili
Journal:  J Interv Card Electrophysiol       Date:  2010-01       Impact factor: 1.900

10.  Pulmonary vein isolation of symptomatic refractory paroxysmal and persistent atrial fibrillation: A single centre and single operator experience in the Netherlands.

Authors:  E S Tan; B A Mulder; M Rienstra; A C P Wiesfeld; S Ahmed; F Zijlstra; I C Van Gelder
Journal:  Neth Heart J       Date:  2009-10       Impact factor: 2.380

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.