Literature DB >> 14579858

A semi-automatic method for developing an anthropomorphic numerical model of dielectric anatomy by MRI.

M Mazzurana1, L Sandrini, A Vaccari, C Malacarne, L Cristoforetti, R Pontalti.   

Abstract

Complex permittivity values have a dominant role in the overall consideration of interaction between radiofrequency electromagnetic fields and living matter, and in related applications such as electromagnetic dosimetry. There are still some concerns about the accuracy of published data and about their variability due to the heterogeneous nature of biological tissues. The aim of this study is to provide an alternative semi-automatic method by which numerical dielectric human models for dosimetric studies can be obtained. Magnetic resonance imaging (MRI) tomography was used to acquire images. A new technique was employed to correct nonuniformities in the images and frequency-dependent transfer functions to correlate image intensity with complex permittivity were used. The proposed method provides frequency-dependent models in which permittivity and conductivity vary with continuity--even in the same tissue--reflecting the intrinsic realistic spatial dispersion of such parameters. The human model is tested with an FDTD (finite difference time domain) algorithm at different frequencies; the results of layer-averaged and whole-body-averaged SAR (specific absorption rate) are compared with published work, and reasonable agreement has been found. Due to the short time needed to obtain a whole body model, this semi-automatic method may be suitable for efficient study of various conditions that can determine large differences in the SAR distribution, such as body shape, posture, fat-to-muscle ratio, height and weight.

Entities:  

Mesh:

Year:  2003        PMID: 14579858     DOI: 10.1088/0031-9155/48/19/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

Review 1.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

Review 2.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

3.  Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models.

Authors:  Brian B Beard; Wolfgang Kainz
Journal:  Biomed Eng Online       Date:  2004-10-13       Impact factor: 2.819

Review 4.  Current state of the art of regional hyperthermia treatment planning: a review.

Authors:  H P Kok; P Wust; P R Stauffer; F Bardati; G C van Rhoon; J Crezee
Journal:  Radiat Oncol       Date:  2015-09-17       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.