Literature DB >> 1457854

Quantitation of right ventricular shape changes after left ventricular assist device implantation.

W A Mandarino1, S Morita, R L Kormos, A Kawai, L G Deneault, T A Gasior, B Losken, B P Griffith.   

Abstract

Complex effects of left (LV) and right ventricular (RV) interaction account for changes in RV function during LV assist device (LVAD) support. It has been hypothesized that changes in RV cross-sectional shape (RVS) may be a contributing factor in the development of RV dysfunction during LVAD support. To test the hypothesis that the RVS would become more circular as a result of septal shift during LVAD support, 13 patients were studied before and after LVAD implantation. The shape of the RV was quantified using a shape factor (SF) that was equal to (4 x pi x area)/P2, where P is the perimeter of RVS. The RV area and perimeter were measured from digitized images of the RV obtained by transesophageal echocardiography in patients before and after LVAD implantation. The group SF increased considerably after LVAD (SFpre = 0.78 +/- 0.12 versus SFpost = 0.88 +/- 0.07, p < 0.05). Patients were divided into three groups: 1) patients whose RV exhibited a low SF pre-LVAD that increased significantly, 2) those with a moderate SF pre-LVAD that increased slightly, and 3) those who had high pre-LVAD SF (< 0.90) that did not change. The decompression of the LV caused by LVAD implantation results in a shift of the septum from right to left, increasing SF. This increase is more pronounced in some patients. Quantitation of the degree of RV SF change may help predict the development of RV failure during LVAD support.

Entities:  

Mesh:

Year:  1992        PMID: 1457854     DOI: 10.1097/00002480-199207000-00026

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

Review 1.  Right ventricular failure--a continuing problem in patients with left ventricular assist device support.

Authors:  Ranjit John; Sangjin Lee; Peter Eckman; Kenneth Liao
Journal:  J Cardiovasc Transl Res       Date:  2010-09-01       Impact factor: 4.132

2.  Right ventricular afterload sensitivity dramatically increases after left ventricular assist device implantation: A multi-center hemodynamic analysis.

Authors:  Brian A Houston; Rohan J Kalathiya; Steven Hsu; Rahul Loungani; Mary E Davis; Samuel T Coffin; Nicholas Haglund; Simon Maltais; Mary E Keebler; Peter J Leary; Daniel P Judge; Gerin R Stevens; John Rickard; Chris M Sciortino; Glenn J Whitman; Ashish S Shah; Stuart D Russell; Ryan J Tedford
Journal:  J Heart Lung Transplant       Date:  2016-02-09       Impact factor: 10.247

3.  Right ventricular dysfunction following continuous flow left ventricular assist device placement in 51 patients: predicators and outcomes.

Authors:  Siyamek Neragi-Miandoab; Daniel Goldstein; Ricardo Bello; Robert Michler; David D'Alessandro
Journal:  J Cardiothorac Surg       Date:  2012-06-27       Impact factor: 1.637

4.  The Use of Berlin Heart EXCOR VAD in Children Less than 10 kg: A Single Center Experience.

Authors:  Arianna Di Molfetta; Fabrizio Gandolfo; Sergio Filippelli; Gianluigi Perri; Luca Di Chiara; Roberta Iacobelli; Rachele Adorisio; Isabella Favia; Alessandra Rizza; Giuseppina Testa; Matteo Di Nardo; Antonio Amodeo
Journal:  Front Physiol       Date:  2016-12-06       Impact factor: 4.566

5.  Diastolic Plateau - Invasive Hemodynamic Marker of Adverse Outcome Among Left Ventricular Assist Device Patients.

Authors:  Avishay Grupper; Afek Kodesh; Jacob Lavee; Paul Fefer; Israel M Barbash; Dan Elian; Alexander Kogan; Avi Morgan; Amit Segev; Elad Maor
Journal:  Front Cardiovasc Med       Date:  2022-04-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.