Literature DB >> 1457540

Demonstration of digital radiographs by means of ink jet-printed paper copies: pilot study.

T Kirkhorn1, M Kehler, J Nilsson, K Lyttkens, B Andersson, N G Holmer.   

Abstract

Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image source to printer. Different versions of paper prints and viewing conditions were compared to find the optimum alternative. The evaluation has been performed to maximize the quality of the paper images to make them conform with the corresponding film prints and monitor images as much as possible. The continuous ink jet technique offers high-quality prints on paper at a considerably lower cost per copy compared with the cost of a film print. With a future switch-over from diagnosing of digital images on film to diagnosing them on monitors, hard copies for demonstration purposes will occasionally be needed. This need can be filled by ink jet-printed paper copies.

Mesh:

Year:  1992        PMID: 1457540     DOI: 10.1007/bf03167806

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  3 in total

1.  Ink jet color printing of digital medical images.

Authors:  J Nilsson; T Johansson; N G Holmer; C H Hertz
Journal:  Acta Radiol       Date:  1990-07       Impact factor: 1.990

2.  The use of ink jets in ultrasound registrations.

Authors:  T Johansson; J Nilsson; L O Almquist; N G Holmer
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

Review 3.  Digital radiography of the chest: promises and problems [publihsed erratum appears in AJR 1988 Sep;151(3):preceding 641].

Authors:  L R Goodman; C R Wilson; W D Foley
Journal:  AJR Am J Roentgenol       Date:  1988-06       Impact factor: 3.959

  3 in total
  2 in total

1.  Ink-jet printout of radiographs on transparent film and glossy paper versus monitor display: an ROC analysis.

Authors:  Sebastian Kühl; Frank Krummenauer; Dorothea Dagassan-Berndt; Thomas J Lambrecht; Bernd d'Hoedt; Ralf Kurt Willy Schulze
Journal:  Clin Oral Investig       Date:  2010-03-20       Impact factor: 3.573

2.  Evaluation of the image quality of ink-jet printed paper copies of digital chest radiographs as compared with film: a receiver operating characteristic study.

Authors:  K Lyttkens; T Kirkhorn; M Kehler; B Andersson; A Ebbesen; P Hochbergs; O Jarlman; C G Lindberg; N G Holmer
Journal:  J Digit Imaging       Date:  1994-05       Impact factor: 4.056

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.