Literature DB >> 14563143

Clinical and radiological evaluation of the Codman semiconstrained load-sharing anterior cervical plate: prospective multicenter trial and independent blinded evaluation of outcome.

Steven Casha1, Michael G Fehlings.   

Abstract

OBJECT: Semiconstrained load-sharing implants for spinal fixation accommodate change in the screw-plate interface as bone grafts shrink. The authors evaluated the clinical and radiological outcome in patients after placement of the Codman anterior cervical plate (ACP) system, which allows change in the screw-plate angle.
METHODS: The authors undertook a 10-center prospective study with independent blinded evaluation. All patients underwent cervical fusion and placement of ACPs. Clinical and radiological evaluations were performed at 1, 3, 6, 12, and 24 months. Radiographs were examined for screw angles, construct height, fusion, and screw fracture or displacement. One hundred ninety-five patients were enrolled. The mean follow-up period was 17 months. At 24 months neurological improvement was demonstrated in 68.7% and pain improvement in 76.6% of the patients. Fusion was successful in 93.8%. Varying degrees (most minor) of hardware-related failure occurred in 10.4% of cases; however, reoperation was required in only four (2.1%). A significant change in screw angles occurred over time (mean 6.4 degrees in caudal screw angle [p < 0.001] and 2.4 degrees in the rostral screw angle [p = 0.003]). These changes plateaued by 6 months. A change in construct height (mean 3.48 mm) occurred by 6 months (p < 0.05).
CONCLUSIONS: Based on an independent blinded evaluation, the Codman ACP provides effective fixation with load sharing and is effective in achieving fusion with a 94% success rate. Direct comparison with rigidly locked devices is required to establish definitively the optimal method for anterior cervical fixation.

Entities:  

Mesh:

Year:  2003        PMID: 14563143     DOI: 10.3171/spi.2003.99.3.0264

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  5 in total

1.  Anterior cervical locking plate-related complications; prevention and treatment recommendations.

Authors:  Xie Ning; Yuan Wen; Ye Xiao-Jian; Ni Bin; Chen De-Yu; Xiao Jian-Ru; Jia Lian-Shun
Journal:  Int Orthop       Date:  2007-05-12       Impact factor: 3.075

2.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

3.  Acute cervical epidural hematoma, screw pullout, and esophageal perforation after anterior cervical corpectomy surgery: report of a case.

Authors:  Ye Li; Qing-San Zhu; Jing-Chen Liu; Yun-Tao Wu
Journal:  Int Surg       Date:  2015-02

4.  Diagnosing cervical fusion: a comprehensive literature review.

Authors:  Nanin Sethi; James Devney; Holly L Steiner; K Daniel Riew
Journal:  Asian Spine J       Date:  2008-12-31

Review 5.  4- and 5-level anterior fusions of the cervical spine: review of literature and clinical results.

Authors:  Heiko Koller; Axel Hempfing; Luis Ferraris; Oliver Maier; Wolfgang Hitzl; Peter Metz-Stavenhagen
Journal:  Eur Spine J       Date:  2007-06-29       Impact factor: 3.134

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.