Precision of high-resolution dual energy X-ray absorptiometry of bone mineral status and body composition in small animal models.

E M Lochmüller1, V Jung, A Weusten, U Wehr, E Wolf, F Eckstein.   

Abstract

The purpose of this study was to analyze the in situ precision (reproducibility) of bone mineral and body composition measurements in mice of different body weights and rats, using a high-resolution DXA (dual energy X-ray absorptiometry) scanner. We examined 48 NMRI mice weighing approximately 10 to 60 g, and 10 rats weighing approximately 140 g. Four repeated measurements were obtained on different days. In mice, the standard deviations of repeated measurements ranged from 2.5 to 242 mg for bone mineral content (BMC), from 0.16 to 3.74 g for fat, and from 0.40 to 4.21 g for lean mass. The coefficient of variation in percent (CV%) for BMC/BMD (bone mineral density) was highest in the 10 g mice (12.8% / 4.9%) and lowest in the 40 g mice (3.5% /1.7%). In rats, it was 2.5 /1.2% in the lower extremity, 7.1/3.0 % in the spine, 5.7/2.0 % in the femur, and 3.6%/2.1% in the tibia. The CV% for fat and lean mass in mice was higher than for BMC. The study demonstrates good precision of bone mineral and moderate precision of body composition measurements in small animals, using a high-resolution DXA system. The technique can be used for testing the efficacy of drugs in small animal models, for mutagenesis screens, and for the phenotypic characterization of transgenic mice.

Entities:  

Year:  2001        PMID: 14562264     DOI: 10.22203/ecm.v001a05

Source DB:  PubMed          Journal:  Eur Cell Mater        ISSN: 1473-2262            Impact factor:   3.942


  5 in total

1.  Dual-energy X-ray absorptiometry, peripheral quantitative computed tomography, and micro-computed tomography techniques are discordant for bone density and geometry measurements in the guinea pig.

Authors:  Ivy L Mak; Jason R DeGuire; Paula Lavery; Sherry Agellon; Hope A Weiler
Journal:  J Bone Miner Metab       Date:  2015-06-10       Impact factor: 2.626

2.  The effect of long-term hypogonadism on body composition and morphometry of aged male Wistar rats.

Authors:  V Borbélyová; V Šarayová; E Renczés; J Čonka; J Janko; K Šebeková; K Štefíková; D Ostatníková; P Celec
Journal:  Physiol Res       Date:  2021-12-31       Impact factor: 1.881

3.  Long-term experiment to study the development, interaction, and influencing factors of DEXA parameters.

Authors:  Helmut Fuchs; Christine Gau; Wolfgang Hans; Valerie Gailus-Durner; Martin Hrabě de Angelis
Journal:  Mamm Genome       Date:  2013-10-06       Impact factor: 2.957

4.  Guidelines for Dual Energy X-Ray Absorptiometry Analysis of Trabecular Bone-Rich Regions in Mice: Improved Precision, Accuracy, and Sensitivity for Assessing Longitudinal Bone Changes.

Authors:  Jiayu Shi; Soonchul Lee; Michael Uyeda; Justine Tanjaya; Jong Kil Kim; Hsin Chuan Pan; Patricia Reese; Louis Stodieck; Andy Lin; Kang Ting; Jin Hee Kwak; Chia Soo
Journal:  Tissue Eng Part C Methods       Date:  2016-04-15       Impact factor: 3.056

5.  A new technique for precisely and accurately measuring lumbar spine bone mineral density in mice using clinical dual energy X-ray absorptiometry (DXA).

Authors:  Ranjitha Katikaneni; Adharsh Ponnapakkam; Eric Miller; Tulasi Ponnapakkam; Robert C Gensure
Journal:  Toxicol Mech Methods       Date:  2009-03       Impact factor: 2.987

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.