Literature DB >> 14560404

All-polyethylene and metal-backed tibial components in total knee arthroplasty: a matched pair analysis of functional outcome.

Soheil Najibi1, Richard Iorio, Jonathan W Surdam, William Whang, David Appleby, William L Healy.   

Abstract

A group of 98 patients who had primary unilateral total knee arthroplasty (TKA) with cemented, posterior-stabilized knee implants for osteoarthritis were matched for age, diagnosis, weight, body mass index, and presence of comorbid conditions. The patients were followed up with clinical, radiographic, and outcome measures including SF-36 scales and patient outcome questionnaires. Forty-nine patients had all-polyethylene tibial implants (APT), and 49 patents had metal backed tibial implants (MBT) with similar knee implant design and articular geometry. There is no difference among these patient cohorts in the clinical performance or functional outcome of TKA using APT or MBT components in primary TKA at intermediate term follow-up. In consideration of concerns about polyethylene wear, osteolysis, and cost associated with MBT components, these findings may present an opportunity for quality improvement and cost savings with increased utilization of APT in TKA operations.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14560404     DOI: 10.1016/s0883-5403(03)00304-8

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.

Authors:  S M Thompson; D Yohuno; W N Bradley; A D Crocombe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-22       Impact factor: 4.342

3.  All-polyethylene tibial components in obese patients are associated with low failure at midterm followup.

Authors:  David F Dalury; Kimberly K Tucker; Todd C Kelley
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

Review 4.  All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.

Authors:  Klaas Auke Nouta; Wiebe C Verra; Bart G Pijls; Jan W Schoones; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2012-09-13       Impact factor: 4.176

5.  All-polyethylene and metal-backed tibial components are equivalent with BMI of less than 37.5.

Authors:  Jared Toman; Richard Iorio; William L Healy
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

Review 6.  All-polyethylene versus metal-backed tibial component in total knee arthroplasty.

Authors:  Umile Giuseppe Longo; Mauro Ciuffreda; Valerio D'Andrea; Nicholas Mannering; Joel Locher; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-21       Impact factor: 4.342

7.  Survivorship comparison of all-polyethylene and metal-backed tibial components in cruciate-substituting total knee arthroplasty--Chinese experience.

Authors:  Bin Shen; Jing Yang; Zongke Zhou; Pengde Kang; Liao Wang; Fuxing Pei
Journal:  Int Orthop       Date:  2008-08-08       Impact factor: 3.075

8.  All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.

Authors:  Jean Brihault; Alessandro Navacchia; Silvia Pianigiani; Luc Labey; Ronny De Corte; Valerio Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-10       Impact factor: 4.342

9.  Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.

Authors:  Tao Cheng; Guoyou Zhang; Xianlong Zhang
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

10.  A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY.

Authors:  Marco Antônio Percope de Andrade; Juliano Rodrigues Dos Santos; Luiz Gustavo Alves Gonzaga; Guilherme Moreira Abreu E Silva
Journal:  Rev Bras Ortop       Date:  2015-11-17
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.