Literature DB >> 14560272

Effect of saliva on shear bond strength of an orthodontic adhesive used with moisture-insensitive and self-etching primers.

Irene L Zeppieri1, Chun-Hsi Chung, Francis K Mante.   

Abstract

The purpose of this study was to investigate the effect of saliva contamination on the shear bond strength of an orthodontic adhesive used with Transbond Moisture-Insensitive Primer (MIP, 3M Unitek, Monrovia, Calif) and Transbond Plus Self-Etching Primer (SEP, 3M Unitek). Hydrophobic Transbond XT primer (XT, 3M Unitek) was used as a control. A total of 162 extracted premolars were collected and divided equally into 9 groups of 18 teeth each, and brackets were bonded with Transbond XT adhesive (3M Unitek) under different experimental conditions: (1) control: etch/dry/XT, (2) etch/dry/MIP, (3) etch/dry/MIP/wet (saliva)/MIP, (4) etch/wet/MIP, (5) etch/wet/MIP/wet/MIP, (6) dry/SEP, (7) dry/SEP/wet/SEP, (8) wet/SEP, and (9) wet/SEP/wet/SEP. Shear bond strength of each sample was examined with a testing machine. The results showed that the control group had the highest mean shear bond strength (group 1, 21.3 +/- 6.8 MPa), followed by the MIP group in a dry field (group 2, 20.7 +/- 5.0 MPa). No significant difference was found between groups 1 and 2. Groups 3 through 9 had similar mean strengths, ranging from 12.7 to 15.0 MPa (P >.05), which were significantly lower than in groups 1 and 2 (P <.05). There was no significant difference in bond-failure site among the 9 groups. It was concluded that (1) Transbond XT adhesive with Transbond XT primer and MIP in a dry field yields similar bond strengths, which are greater than all other groups, (2) saliva contamination significantly lowers the bond strength of Transbond MIP, (3) saliva has no effect on the bond strength of Transbond SEP, (4) Transbond XT adhesive with Transbond MIP and SEP might have clinically acceptable bond strengths in either dry or wet fields.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14560272     DOI: 10.1016/s0889-5406(03)00405-0

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  17 in total

1.  Effects of different application durations of ER:YAG laser on intrapulpal temperature change during debonding.

Authors:  Didem Nalbantgil; M Oguz Oztoprak; Murat Tozlu; Tülin Arun
Journal:  Lasers Med Sci       Date:  2010-06-10       Impact factor: 3.161

2.  Effects of moisture conditions of dental enamel surface on bond strength of brackets bonded with moisture-insensitive primer adhesive system.

Authors:  Toshiya Endo; Rieko Ozoe; Sugako Sanpei; Koichi Shinkai; Yoshiroh Katoh; Shohachi Shimooka
Journal:  Odontology       Date:  2008-07-27       Impact factor: 2.634

3.  Does a reduction of polymerization time and bonding steps affect the bond strength of brackets?

Authors:  Timea Lamper; Stefanie Steinhäuser-Andresen; Karin C Huth; Nicoleta Ilie; Ekaterini Paschos
Journal:  Clin Oral Investig       Date:  2011-03-30       Impact factor: 3.573

4.  Self-etch adhesives for the bonding of orthodontic brackets: faster, stronger, safer?

Authors:  Timea Lamper; Nicoleta Ilie; Karin C Huth; Ingrid Rudzki; Andrea Wichelhaus; Ekaterini Paschos
Journal:  Clin Oral Investig       Date:  2013-02-14       Impact factor: 3.573

5.  Blood contamination effect on shear bond strength of an orthodontic hydrophilic resin.

Authors:  Taís de Morais Alves da Cunha; Bruna Ariela Behrens; Denise Nascimento; Luciana Borges Retamoso; Luís Filipe Siu Lon; Orlando Tanaka; Odilon Guariza Filho
Journal:  J Appl Oral Sci       Date:  2012-02       Impact factor: 2.698

6.  Comparison of the Effects of Various Methods Used to Remove Adhesive from Tooth Surfaces on Surface Roughness and Temperature Changes in the Pulp Chamber.

Authors:  Mihri Amasyalı; Fidan Alakuş Sabuncuoğlu; Şeyda Ersahan; Elif Aybala Oktay
Journal:  Turk J Orthod       Date:  2019-09-01

7.  Effect of moisture, saliva, and blood contamination on the shear bond strength of brackets bonded with a conventional bonding system and self-etched bonding system.

Authors:  Mandava Prasad; Shamil Mohamed; Krishna Nayak; Sharath Kumar Shetty; Ashok Kumar Talapaneni
Journal:  J Nat Sci Biol Med       Date:  2014-01

8.  Shear bond strength comparison of moisture-insensitive primer and self-etching primer.

Authors:  Arunima Goswami; Borah Mitali; Bk Roy
Journal:  J Orthod Sci       Date:  2014-07

9.  Moisture insensitive primer: A myth or truth.

Authors:  Chandresh Shukla; Rajkumar Maurya; Upendra Jain; Ankur Gupta; Jayshree Garg
Journal:  J Orthod Sci       Date:  2014-10

10.  Shear bond strengths of different adhesive systems to biodentine.

Authors:  Mesut Enes Odabaş; Mehmet Bani; Resmiye Ebru Tirali
Journal:  ScientificWorldJournal       Date:  2013-10-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.