Literature DB >> 14560269

Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations.

Vittorio Cacciafesta1, Maria Francesca Sfondrini, Andrea Ricciardi, Andrea Scribante, Catherine Klersy, Ferdinando Auricchio.   

Abstract

This study measured and compared the level of frictional resistance generated between stainless steel self-ligating brackets (Damon SL II, SDS Ormco, Glendora, Calif), polycarbonate self-ligating brackets (Oyster, Gestenco International, Göthenburg, Sweden), and conventional stainless steel brackets (Victory Series, 3M Unitek, Monrovia, Calif), and 3 different orthodontic wire alloys: stainless steel (Stainless Steel, SDS Ormco), nickel-titanium (Ni-Ti, SDS Ormco), and beta-titanium (TMA, SDS Ormco). All brackets had a.022-in slot, whereas the orthodontic wire alloys were tested in 3 different sections:.016,.017 x.025, and.019 x 0.025 in. Each of the 27 bracket and archwire combinations was tested 10 times, and each test was performed with a new bracket-wire sample. Both static and kinetic friction were measured on a custom-designed apparatus. All data were statistically analyzed (Kruskal-Wallis and Mann Whitney U tests). Stainless steel self-ligating brackets generated significantly lower static and kinetic frictional forces than both conventional stainless steel and polycarbonate self-ligating brackets, which showed no significant differences between them. Beta-titanium archwires had higher frictional resistances than stainless steel and nickel-titanium archwires. No significant differences were found between stainless steel and nickel-titanium archwires. All brackets showed higher static and kinetic frictional forces as the wire size increased.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14560269     DOI: 10.1016/s0889-5406(03)00504-3

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  45 in total

1.  Comparative Evaluation of Frictional Properties, Load Deflection Rate and Surface Characteristics of Different Coloured TMA Archwires - An Invitro Study.

Authors:  Arul Pradeep Aloysius; Devaki Vijayalakshmi; Nagachandran Kandasamy Soundararajan; Vijaykumar Neelam Manohar; Nayeemullah Khan
Journal:  J Clin Diagn Res       Date:  2015-12-01

2.  A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type.

Authors:  Souk Min Lee; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2015-01-26       Impact factor: 1.372

3.  Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations.

Authors:  Maria Regina Guerra Monteiro; Licinio Esmeraldo da Silva; Carlos Nelson Elias; Oswaldo de Vasconcellos Vilella
Journal:  J Appl Oral Sci       Date:  2014-06       Impact factor: 2.698

4.  In-vitro study of surface changes in fixed orthodontic appliances following air polishing with Clinpro Prophy and Air-Flow.

Authors:  Benedict Wilmes; Shervin Vali; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2009-12-09       Impact factor: 1.938

5.  Tooth movement rate and anchorage lost during canine retraction: A maxillary and mandibular comparison.

Authors:  Andre da C Monini; Luiz G Gandini; Alexandre P Vianna; Renato P Martins; Helder B Jacob
Journal:  Angle Orthod       Date:  2019-02-11       Impact factor: 2.079

6.  Ceramic brackets and low friction : A possible synergy in patients requiring multiple MRI scanning.

Authors:  Matteo Camporesi; Mariana Bulhoes Galvão; André Tortamano; Gladys Cristina Dominguez; Nicolò Defraia; Efisio Defraia; Lorenzo Franchi
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

7.  Influence of thermal or chemical degradation on the frictional force of an experimental coated NiTi wire.

Authors:  Ana Maria Bezerra Bandeira; Marcia Pereira Alves dos Santos; Gino Pulitini; Carlos Nelson Elias; Marysilva Ferreira da Costa
Journal:  Angle Orthod       Date:  2011-02-07       Impact factor: 2.079

8.  Friction behavior and other material properties of nickel-titanium and titanium-molybdenum archwires following electrochemical surface refinement.

Authors:  Miriam Julia Meier; Christoph Bourauel; Jan Roehlike; Susanne Reimann; Ludger Keilig; Bert Braumann
Journal:  J Orofac Orthop       Date:  2014-07-06       Impact factor: 1.938

9.  Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study.

Authors:  Graziane Olímpio Pereira; Carla Maria Melleiro Gimenez; Lucas Prieto; Marcos Gabriel do Lago Prieto; Roberta Tarkany Basting
Journal:  Dental Press J Orthod       Date:  2016 Jul-Aug

10.  Comparison of static friction with self-ligating, modified slot design and conventional brackets.

Authors:  Raquel Morais Castro; Perrin Smith Neto; Martinho Campolina Rebello Horta; Matheus Melo Pithon; Dauro Douglas Oliveira
Journal:  J Appl Oral Sci       Date:  2013 Jul-Aug       Impact factor: 2.698

View more