Literature DB >> 14558995

Microfluidic enzyme immunosensors with immobilised protein A and G using chemiluminescence detection.

Julia Yakovleva1, Richard Davidsson, Martin Bengtsson, Thomas Laurell, Jenny Emnéus.   

Abstract

Affinity proteins were covalently immobilised on silicon microchips with overall dimensions of 13.1 x 3.2 mm, comprising 42 porous flow channels of 235 microm depth and 25 microm width, and used to develop microfluidic immunosensors based on horseradish peroxidase (HRP), catalysing the chemiluminescent oxidation of luminol/p-iodophenol (PIP). Different hydrophilic polymers with long flexible chains (polyethylenimine (PEI), dextran (DEX), polyvinyl alcohol, aminodextran) and 3-aminopropyltriethoxysilane (APTS) were employed for modification of the silica surfaces followed by attachment of protein A or G. The resulting immunosensors were compared in an affinity capture assay format, where the competition between the labelled antigen and the analyte for antibody-binding sites took place in the bulk of the solution. The formed immunocomplexes were then trapped by the microchip affinity capture support and the amount of bound tracer was monitored by injection of luminol, PIP and H2O2. All immunosensors were capable of detecting atrazine at the sub-microg l(-1) level. The most sensitive assays were obtained with PEI and DEX polymer modified supports and immobilised protein G, with limits of detection of 0.006 and 0.010 microg l(-1), and IC50 values of 0.096 and 0.130 microg l(-1), respectively. The protein G based immunosensors were regenerated with 0.4 M glycine-HCl buffer pH 2.2, with no loss of activity observed for a storage and operating period of over 8 months. To estimate the applicability of the immunosensors to the analysis of real samples, PEI and DEX based protein G microchips were used to detect atrazine in surface water and fruit juice, spiked with known amounts of the atrazine, giving recovery values of 87-102 and 88-124% at atrazine fortification levels of 0.5-3 and 80-240 microg l(-1), respectively.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14558995     DOI: 10.1016/s0956-5663(03)00126-x

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

Review 1.  Protein immobilization techniques for microfluidic assays.

Authors:  Dohyun Kim; Amy E Herr
Journal:  Biomicrofluidics       Date:  2013-07-30       Impact factor: 2.800

2.  On-chip microfluidic systems for determination of L-glutamate based on enzymatic recycling of substrate.

Authors:  W Laiwattanapaisal; J Yakovleva; M Bengtsson; T Laurell; S Wiyakrutta; V Meevootisom; O Chailapakul; J Emnéus
Journal:  Biomicrofluidics       Date:  2009-03-16       Impact factor: 2.800

3.  Synthesis of functionalized ZnSe nanoparticles and their applications in the determination of bovine serum albumin.

Authors:  Li Li; Fenfen Zhang; Yaping Ding; Yaping Wang; Lulu Zhang
Journal:  J Fluoresc       Date:  2008-10-30       Impact factor: 2.217

4.  Biotechnological tools for environmental sustainability: prospects and challenges for environments in Nigeria-a standard review.

Authors:  Chukwuma S Ezeonu; Richard Tagbo; Ephraim N Anike; Obinna A Oje; Ikechukwu N E Onwurah
Journal:  Biotechnol Res Int       Date:  2012-05-03

5.  Multitarget, quantitative nanoplasmonic electrical field-enhanced resonating device (NE2RD) for diagnostics.

Authors:  Fatih Inci; Chiara Filippini; Murat Baday; Mehmet Ozgun Ozen; Semih Calamak; Naside Gozde Durmus; ShuQi Wang; Emily Hanhauser; Kristen S Hobbs; Franceline Juillard; Ping Ping Kuang; Michael L Vetter; Margot Carocci; Hidemi S Yamamoto; Yuko Takagi; Umit Hakan Yildiz; Demir Akin; Duane R Wesemann; Amit Singhal; Priscilla L Yang; Max L Nibert; Raina N Fichorova; Daryl T-Y Lau; Timothy J Henrich; Kenneth M Kaye; Steven C Schachter; Daniel R Kuritzkes; Lars M Steinmetz; Sanjiv S Gambhir; Ronald W Davis; Utkan Demirci
Journal:  Proc Natl Acad Sci U S A       Date:  2015-07-20       Impact factor: 12.779

Review 6.  Fish-on-a-chip: a sensitive detection microfluidic system for Alzheimer's disease.

Authors:  Jasmine P Devadhasan; Sanghyo Kim; Jeongho An
Journal:  J Biomed Sci       Date:  2011-05-28       Impact factor: 8.410

7.  Battery-free fully integrated microfluidic light source for portable lab-on-a-chip applications.

Authors:  Filippo Storti; Silvio Bonfadini; Luigino Criante
Journal:  Sci Rep       Date:  2020-07-31       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.