Takashi Miyado1, Hidenori Nagai, Sahori Takeda, Keiitsu Saito, Keiichi Fukushi, Yasukazu Yoshida, Shin-ichi Wakida, Etsuo Niki.
Abstract
In order to improve NO2- peak height and obtain a convenient buffer system for the assay of nitrogen monooxide metabolites, we developed a novel running buffer for the simultaneous determination of nitrite and nitrate in human serum by capillary electrophoresis. The addition of cetyltrimethylammonium chloride to the running buffer resulted in high-speed separation using reverse electroosmotic flow. Highly sensitive determination was also achieved using stacking with 10-fold diluted sample solutions. The samples were injected hydrodynamically for 100 s into a 50 cm x 75 microm I.D. capillary. The separation voltage was 10 kV (negative polarity). UV detection was performed at 214 nm. We obtained complete separation of nitrite and nitrate in deproteinized human serum within 6 min with optimum analytical conditions. Linear calibration curves for nitrite and nitrate for both peak height and peak area were obtained with standard addition method. The limits of detection obtained at a signal-to-noise ratio of 3 for nitrite and nitrate were 4.1 and 2.0 microM, while the values of relative standard deviation of peak height were 2.4 and 2.6%, respectively.Entities:
Mesh:
Substances:
Year: 2003 PMID: 14558625 DOI: 10.1016/s0021-9673(03)00944-0
Source DB: PubMed Journal: J Chromatogr A ISSN: 0021-9673 Impact factor: 4.759