Literature DB >> 14557931

Cementless total hip arthroplasty using porous-coated Biomet acetabular cups (Hexloc and Ringloc types).

Kengo Yamamoto1, Atsuhiro Imakiire, Takaaki Shishido, Toshinori Masaoka, Ryuji Koizumi, Koji Ito, Keiji Sano.   

Abstract

This study examined the mid-term (more than 5 years) results of cementless total hip arthroplasty (THA) using Biomet acetabular cups (locking mechanism: Hexloc type or Ringloc type). A series of 58 patients (70 hips) who had undergone cementless THA at our department were available for inclusion in this study. The average age at surgery was 55.2 years, and the average follow-up was 6 years 10 months. Osteolysis occurred in five cases. In the group with osteolysis, the average annual linear wear was 0.18 mm/year, and in the group without osteolysis it was 0.10 mm/year. The higher linear wear rate in the osteolysis group was statistically significant compared to that in the nonosteolysis group. The age of the patient was closely related to polyethylene (PE) wear in the Hexloc group but not in the Ringloc group. In the Ringloc group there was no close correlation between the thickness of the PE liner and the average annual linear wear, whereas in the Hexloc group the thicker liner had significantly less annual linear wear. It was thought that PE wear of the Hexloc cup was more susceptible to the age of the patient at surgery and the PE thickness than that of the Ringloc cup owing to several structural differences, such as rotational stability and conformity between the metal cup and the PE liner.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14557931     DOI: 10.1007/s00776-003-0689-8

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  5 in total

Review 1.  Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.

Authors:  Hugo C van der Veen; Hans-Peter W van Jonbergen; Rudolf W Poolman; Sjoerd K Bulstra; Jos J A M van Raay
Journal:  Int Orthop       Date:  2012-12-11       Impact factor: 3.075

2.  Effect of stem alignment on long-term outcomes of total hip arthroplasty with cementless Bi-Metric femoral components.

Authors:  Takaaki Shishido; Toshiyuki Tateiwa; Yasuhito Takahashi; Toshinori Masaoka; Tsunehito Ishida; Kengo Yamamoto
Journal:  J Orthop       Date:  2018-01-16

3.  Survival of Bi-Metric femoral stems in 77 total hip arthroplasties for juvenile chronic arthritis.

Authors:  C C Lybäck; C O Lybäck; A Kyrö; H J Kautiainen; E A Belt
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

4.  The Ringloc liner compared with the Hexloc liner in total hip arthroplasty.

Authors:  Sköldenberg Olof; Salemyr Mats; Muren Olle; Johansson Ake; Ahl Torbjörn; Bodén Henrik
Journal:  Orthop Rev (Pavia)       Date:  2009-10-10

5.  No improvement in long-term wear and revision rates with the second-generation Biomet cup (RingLoc) in young patients: 141 hips followed for median 12 years.

Authors:  Bart Boesenach; Huub J L van der Heide; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2011-11-09       Impact factor: 3.717

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.