Literature DB >> 14555897

Effects of contact lenses on corneal thickness and corneal curvature during usage.

Bariş Yeniad1, Bülent Yiğit, Halim Işsever, Lale Közer Bilgin.   

Abstract

PURPOSE: To investigate the effects of contact lenses on corneal thickness and curvature.
METHODS: Eighty-four eyes of 45 patients (26 female and 19 male) wearing contact lens for the first time with a median age of 23.04 +/- 7.2 years (range, 15-44 years) were included in the study. After all patients had undergone a routine ophthalmic examination, corneal thickness measurements in nine regions and corneal topography were performed before wearing contact lenses and after 1 month, 6 months, and 12 months. Patients were classified into three groups according to duration of wear. Groups were also classified into two subgroups according to the lens type (rigid gas-permeable and soft contact lenses).
RESULTS: Mean visual acuity was 0.82 +/- 0.26 with spectacles and 0.92 +/- 0.26 with contact lenses. At the end of 1 month, statistically significant corneal thinning and thickening were noted in different regions in group 1. In group 2, statistically significant corneal thinning was noted in all regions with soft contact lenses and rigid gas-permeable contact lenses except in the inferior temporal region at the end of 6 months. In group 3, corneal thinning was noted in all regions with soft contact lenses and rigid gas-permeable contact lenses. This corneal thinning was statistically significant in all regions with the soft contact lenses except in the inferior nasal region and with rigid gas-permeable contact lenses except in the central region. When corneal curvatures were examined, corneal flattening was seen in groups 1 and 2. In group 3, corneal steepening was noted.
CONCLUSIONS: Soft contact lenses and rigid gas-permeable contact lenses cause corneal thickening and corneal flattening in the first months, but they cause corneal thinning and corneal steepening with time. These alterations can be evaluated as evidence that contact lenses negatively influence corneal physiology.

Entities:  

Mesh:

Year:  2003        PMID: 14555897     DOI: 10.1097/01.icl.0000086494.50288.70

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  3 in total

1.  Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment.

Authors:  Khaled Alzahrani; Cristina Cristian; Sophie Harper; Fiona Carley; Arun Brahma; Debbie Morley; M Chantal Hillarby
Journal:  Clin Ophthalmol       Date:  2018-09-04

2.  Sirius Scheimpflug-Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis.

Authors:  Yili Jin; Colm McAlinden; Yong Sun; Daizong Wen; Yiran Wang; Jinjin Yu; Ke Feng; Benhao Song; Qinmei Wang; Shihao Chen; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2021-02-18

3.  Does Long-term Soft Contact Lens Wear Affect Corneal and Anterior Chamber Parameters?

Authors:  Cemal Çavdarlı; Pınar Topçu-Yılmaz
Journal:  Turk J Ophthalmol       Date:  2018-09-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.