Literature DB >> 14551750

Left atrial versus left ventricular input function for quantification of the myocardial blood flow with nitrogen-13 ammonia and positron emission tomography.

Jens D Hove1, Hidehiro Iida, Klaus F Kofoed, Jacob Freiberg, Søren Holm, Henning Kelbaek.   

Abstract

Flow quantitation with nitrogen-13 ammonia ((13)NH(3)) and positron emission tomography (PET) is dependent on an accurate blood time-activity curve. This is conveniently derived from the PET images by drawing a region of interest in the left ventricular cavity. The blood time-activity curve obtained in this way, however, may contain spillover from the myocardial wall. The purpose of this study was to analyse the effect of wall to blood pool spillover. Additionally, we analysed the application of a left atrial input function. Using computer simulations, we investigated the effect of spillover from the myocardial wall to the left ventricular input function and the effect of time delay on the left ventricular input function. An oxygen-15 carbon monoxide PET study of seven normal volunteers was used to investigate possible recovery issues regarding the left atrial input function. Finally, (13)NH(3) studies of 31 normal volunteers during rest and dipyridamole stimulation were analysed using either a left atrial or a left ventricular input function. The simulation studies showed that myocardial wall to blood pool spillover causes a considerable underestimation of the regional blood flow values in hyperaemic flow studies. Neither time delay nor recovery issues prevent flow quantitation with a left atrial input function. The (13)NH(3) studies revealed no significant difference between the resting blood flow values, whereas the hyperaemic blood flow values were underestimated by 8% (P<0.01) on average (up to 40% individually) when using a left ventricular input function compared with a left atrial input function. Spillover of activity from the left ventricular wall to the blood time-activity curve is of importance in hyperaemic flow studies using (13)NH(3). Application of a left atrial input function is a possible solution to these issues.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14551750     DOI: 10.1007/s00259-003-1329-4

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  13 in total

1.  Quantification of regional myocardial blood flow using 13N-ammonia and reoriented dynamic positron emission tomographic imaging.

Authors:  W G Kuhle; G Porenta; S C Huang; D Buxton; S S Gambhir; H Hansen; M E Phelps; H R Schelbert
Journal:  Circulation       Date:  1992-09       Impact factor: 29.690

2.  13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.

Authors:  J Krivokapich; G T Smith; S C Huang; E J Hoffman; O Ratib; M E Phelps; H R Schelbert
Journal:  Circulation       Date:  1989-11       Impact factor: 29.690

3.  Factor analysis for extraction of blood time-activity curves in dynamic FDG-PET studies.

Authors:  H M Wu; C K Hoh; Y Choi; H R Schelbert; R A Hawkins; M E Phelps; S C Huang
Journal:  J Nucl Med       Date:  1995-09       Impact factor: 10.057

4.  Measurement of arterial tracer concentrations from cardiac PET images.

Authors:  K Yoshida; M Endo; H Fukuda; A Kagaya; T Himi; Y Masuda; Y Inagaki; T Iinuma; T Yamasaki; Y Tateno
Journal:  J Comput Assist Tomogr       Date:  1995 Mar-Apr       Impact factor: 1.826

5.  Performance characteristics of a whole-body PET scanner.

Authors:  T R DeGrado; T G Turkington; J J Williams; C W Stearns; J M Hoffman; R E Coleman
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

6.  Glucose metabolism in reperfused myocardium measured by [2-18F] 2-fluorodeoxyglucose and PET.

Authors:  K F Kofoed; H Schöder; R J Knight; D B Buxton
Journal:  Cardiovasc Res       Date:  2000-01-14       Impact factor: 10.787

7.  Noninvasive quantification of myocardial blood flow in humans. A direct comparison of the [13N]ammonia and the [15O]water techniques.

Authors:  E U Nitzsche; Y Choi; J Czernin; C K Hoh; S C Huang; H R Schelbert
Journal:  Circulation       Date:  1996-06-01       Impact factor: 29.690

8.  Cerebral blood volume measured with inhaled C15O and positron emission tomography.

Authors:  W R Martin; W J Powers; M E Raichle
Journal:  J Cereb Blood Flow Metab       Date:  1987-08       Impact factor: 6.200

9.  Validation of PET-acquired input functions for cardiac studies.

Authors:  I N Weinberg; S C Huang; E J Hoffman; L Araujo; C Nienaber; M Grover-McKay; M Dahlbom; H Schelbert
Journal:  J Nucl Med       Date:  1988-02       Impact factor: 10.057

10.  Direct comparison of [13N]ammonia and [15O]water estimates of perfusion with quantification of regional myocardial blood flow by microspheres.

Authors:  A Bol; J A Melin; J L Vanoverschelde; T Baudhuin; D Vogelaers; M De Pauw; C Michel; A Luxen; D Labar; M Cogneau
Journal:  Circulation       Date:  1993-02       Impact factor: 29.690

View more
  8 in total

1.  Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET.

Authors:  Hanne M Søndergaard; Mette Marie Madsen; Karin Boisen; Morten Bøttcher; Ole Schmitz; Torsten T Nielsen; Hans Erik Bøtker; Søren B Hansen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-10-11       Impact factor: 9.236

Review 2.  Methodology for quantifying absolute myocardial perfusion with PET and SPECT.

Authors:  Martin A Lodge; Frank M Bengel
Journal:  Curr Cardiol Rep       Date:  2007-04       Impact factor: 2.931

Review 3.  Dynamic whole-body PET imaging: principles, potentials and applications.

Authors:  Arman Rahmim; Martin A Lodge; Nicolas A Karakatsanis; Vladimir Y Panin; Yun Zhou; Alan McMillan; Steve Cho; Habib Zaidi; Michael E Casey; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-29       Impact factor: 9.236

4.  Myocardial perfusion models: a means or an end?

Authors:  Nils P Johnson; K Lance Gould
Journal:  J Nucl Cardiol       Date:  2013-02       Impact factor: 5.952

5.  Short-term repeatability of resting myocardial blood flow measurements using rubidium-82 PET imaging.

Authors:  Matthew Efseaff; Ran Klein; Maria C Ziadi; Rob S Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2012-07-24       Impact factor: 5.952

6.  Clinical evaluation of iterative reconstruction (ordered-subset expectation maximization) in dynamic positron emission tomography: quantitative effects on kinetic modeling with N-13 ammonia in healthy subjects.

Authors:  Jens D Hove; Rune Rasmussen; Jacob Freiberg; Søren Holm; Henning Kelbaek; Klaus E Kofoed
Journal:  J Nucl Cardiol       Date:  2008-04-16       Impact factor: 5.952

7.  Direct inference of Patlak parametric images in whole-body PET/CT imaging using convolutional neural networks.

Authors:  Neda Zaker; Kamal Haddad; Reza Faghihi; Hossein Arabi; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-06-18       Impact factor: 10.057

8.  Added value of myocardial blood flow using 18F-flurpiridaz PET to diagnose coronary artery disease: The flurpiridaz 301 trial.

Authors:  Venkatesh L Murthy; Edward P Ficaro; Jonathan B Moody; Alexis Poitrasson-Rivière; Tomoe Hagio; Christopher Buckley; Richard L Weinberg; James R Corbett
Journal:  J Nucl Cardiol       Date:  2020-01-30       Impact factor: 5.952

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.