| Literature DB >> 14534831 |
W Yinusa1, Y H Li, W Chow, W Y Ho, J C Y Leong.
Abstract
From February 2001 to May 2001, 792 latex gloves used in 100 operations from three orthopaedic sub-specialties (paediatrics, hand and spine) were tested for puncture by a water infusion test. Sixty-nine gloves from 45 operations were punctured, giving an overall glove perforation rate of 8.7% (69/792) and an operative perforation rate of 45% (45/100). The hand operations had the lowest operative perforation rate (19.4%) while the spine operations had the highest (63.6%). The glove perforation rate increased in bony procedures (60% versus 22.5%), in procedures with major instrumentation (66% versus 18%) and in more lengthy procedures. The thumbs and the left index finger had more punctures than other parts. In addition, the glove perforation rate for single gloving was 9.6% (53/552) while that for the inner glove of double gloving was 0.8% (1/120). Based on these findings, we would like to recommend double gloving and regular glove changing in these high-risk surgeries.Entities:
Mesh:
Year: 2003 PMID: 14534831 PMCID: PMC3466585 DOI: 10.1007/s00264-003-0510-5
Source DB: PubMed Journal: Int Orthop ISSN: 0341-2695 Impact factor: 3.075