MLC dosimetric characteristics for small field and IMRT applications.

J E Bayouth1, S M Morrill.   

Abstract

The objective of this work was to measure the performance characteristics of a double-focus multileaf collimator (MLC) for intensity modulated radiation therapy (IMRT), specifically the variation in penumbra and leakage for narrow fields as a function of field position over a 20x27 cm space available for segmented MLC IMRT. Measurements were made with 6 MV x rays through a MLC containing 29 leaf pairs (27 pairs of 1 cm width), and EDR2 film at 10 cm depth in solid water at 100 cm SAD. Films were digitized with 0.17 mm resolution and converted to dose. Interleaf and intraleaf transmission were measured along 11 vertical profile locations. Leaf-end transmission was measured along horizontal profiles for each of 9 different leaf abutments, traveling over a 20 cm range. In-plane penumbra measurements were made through a single leaf retracted, for 7 different leaves. Cross-plane penumbra (leaf-end) measurements were made for all 27 leaf pairs, where the 1 cm field width was placed in 11 different off-axis positions (20 cm range). Interleaf leakage (range 1.0%-1.5%), intraleaf transmission (range 0.6%-0.8%), and leaf-end transmission (range 0.8%-2.7%) were consistent for all leaf pairs at a given abutment position. The penumbra for these 1-cm-wide fields was measured to be 0.36 cm+/-0.03 cm for 99% of the measurements. In conclusion, the penumbra and leakage of the double-focus MLC were remarkably consistent for the range of leaf positions studied, producing dosimetric characteristics that are well suited for IMRT segments where opposing leaf pairs are often separated by 10 mm or less.

Entities:  

Mesh:

Year:  2003        PMID: 14528977     DOI: 10.1118/1.1603743

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Comparison of dosimetric characteristics of 120-leaf and 80-leaf multi-leaf collimators in a Varian linear accelerator for a 6-MV photon beam.

Authors:  R Mohan; K Jayesh; R C Joshi; P Narayanamurthy; Saroj Kumar Das Majumdar; Maha Al-Idirisi
Journal:  Radiol Phys Technol       Date:  2008-07-15

2.  Evaluation of QA software system analysis for the static picket fence test.

Authors:  Julien Boudet; Léone Aubignac; Amandine Beneux; Frédéric Mazoyer; Igor Bessieres
Journal:  J Appl Clin Med Phys       Date:  2022-05-15       Impact factor: 2.243

3.  Leakage-Penumbra effect in intensity modulated radiation therapy step-and-shoot dose delivery.

Authors:  Grigor N Grigorov; James Cl Chow
Journal:  World J Radiol       Date:  2016-01-28

4.  Performance characterization of siemens primus linear accelerator under small monitor unit and small segments for the implementation of step-and-shoot intensity-modulated radiotherapy.

Authors:  P Reena; S Dayananda; Rajeshri Pai; S V Jamema; Tejpal Gupta; D Deepak; S Rajeev
Journal:  J Med Phys       Date:  2006-10

5.  Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system.

Authors:  H Sudahar; P G G Kurup; V Murali; J Velmurugan
Journal:  J Med Phys       Date:  2012-01

6.  Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

Authors:  Dayananda Shamurailatpam Sharma; Prabhakar M Dongre; Vaibav Mhatre; Malhotra Heigrujam
Journal:  J Appl Clin Med Phys       Date:  2011-04-14       Impact factor: 2.102

7.  Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films.

Authors:  Sharifeh A Dini; Rafiq A Koona; John R Ashburn; Ali S Meigoonia
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

8.  Static MLC transmission simulation using two-dimensional ray tracing.

Authors:  David P Adam; Bryan P Bednarz; Sean P Frigo
Journal:  J Appl Clin Med Phys       Date:  2022-05-20       Impact factor: 2.243

9.  Dosimetric evaluation of 120-leaf multileaf collimator in a Varian linear accelerator with 6-MV and 18-MV photon beams.

Authors:  R Mohan; K Jayesh; R C Joshi; Maha Al-Idrisi; P Narayanamurthy; Saroj Kumar Das Majumdar
Journal:  J Med Phys       Date:  2008-07

10.  Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.

Authors:  Than S Kehwar; Anup K Bhardwaj; Shiv K Chakarvarti
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.