Literature DB >> 1452794

Histopathological and microanalytical study of zirconium dioxide and barium sulphate in bone cement.

C E Keen1, G Philip, K Brady, J D Spencer, D A Levison.   

Abstract

AIMS: To report the appearances of zirconium dioxide and barium sulphate in interface membranes, synovium, and other tissues around joint prostheses.
METHODS: Histological sections from 23 specimens were reviewed by light microscopy and polarisation. Scanning electron microscopy and x ray microanalysis were performed on routinely processed paraffin wax sections.
RESULTS: Polyethylene, metals, and polymethylmethacrylate cement debris were easily recognisable. Almost all the cement remnants contained either zirconium dioxide or barium sulphate, confirmed by microanalysis. The contrast media had characteristic light microscopic appearances. Zirconium was identified in macrophages away from cement remnants.
CONCLUSION: The presence of radiographic contrast media in tissues around prosthetic joints is common but not widely recognised.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1452794      PMCID: PMC495029          DOI: 10.1136/jcp.45.11.984

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  15 in total

1.  About radioactivity in some PMMA bone cements.

Authors:  W Hopf; C G Hopf; B Glöbel
Journal:  Acta Orthop Belg       Date:  1990       Impact factor: 0.500

2.  Identification of titanium in human tissues: probable role in pathologic processes.

Authors:  C A Moran; F G Mullick; K G Ishak; F B Johnson; W B Hummer
Journal:  Hum Pathol       Date:  1991-05       Impact factor: 3.466

3.  Identification of titanium pigment in drug addicts' tissues.

Authors:  J C Coelho Filho; R A Moreira; P R Crocker; D A Levison; B Corrin
Journal:  Histopathology       Date:  1991-08       Impact factor: 5.087

4.  The influence of bone and bone cement debris on counterface roughness in sliding wear tests of ultra-high molecular weight polyethylene on stainless steel.

Authors:  L Caravia; D Dowson; J Fisher; B Jobbins
Journal:  Proc Inst Mech Eng H       Date:  1990       Impact factor: 1.617

5.  The causes of femoral head roughening in explanted Charnley hip prostheses.

Authors:  G H Isaac; J R Atkinson; D Dowson; P D Kennedy; M R Smith
Journal:  Eng Med       Date:  1987-07

6.  [Effect of roentgen contrast media in bone cements on connective tissue and bone structures].

Authors:  J Rudigier; R Reck; H J Walde; J Degreif
Journal:  Aktuelle Probl Chir Orthop       Date:  1987

7.  Tissue reactions to joint prostheses and the products of wear and corrosion.

Authors:  P A Revell
Journal:  Curr Top Pathol       Date:  1982

8.  Comparative investigations of regional lymph nodes and pseudocapsules after implantation of joint endoprostheses.

Authors:  I Bos; R Johannisson; U Löhrs; B Lindner; U Seydel
Journal:  Pathol Res Pract       Date:  1990-12       Impact factor: 3.250

9.  The synovial response to intra-articular acrylic cement particles in guinea pigs.

Authors:  G Meachim; G Brooke
Journal:  Biomaterials       Date:  1984-03       Impact factor: 12.479

Review 10.  Implications of metallic corrosion in total knee arthroplasty.

Authors:  K L Wapner
Journal:  Clin Orthop Relat Res       Date:  1991-10       Impact factor: 4.176

View more
  4 in total

1.  In vitro and in vivo biological responses to a novel radiopacifying agent for bone cement.

Authors:  J S Wang; J Diaz; A Sabokbar; N Athanasou; F Kjellson; K E Tanner; I D McCarthy; L Lidgren
Journal:  J R Soc Interface       Date:  2005-03-22       Impact factor: 4.118

2.  Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time.

Authors:  Bernd Fink; Annett Rechtenbach; Hubert Büchner; Sebastian Vogt; Michael Hahn
Journal:  Clin Orthop Relat Res       Date:  2010-07-28       Impact factor: 4.176

3.  Actinomycosis of the jaws--histopathological study of 45 patients shows significant involvement in bisphosphonate-associated osteonecrosis and infected osteoradionecrosis.

Authors:  Torsten Hansen; Martin Kunkel; Erik Springer; Christian Walter; Achim Weber; Ekkehard Siegel; C James Kirkpatrick
Journal:  Virchows Arch       Date:  2007-10-20       Impact factor: 4.064

4.  Mixed material wear particle isolation from periprosthetic tissue surrounding total joint replacements.

Authors:  Ashley A Stratton-Powell; Sophie Williams; Joanne L Tipper; Anthony C Redmond; Claire L Brockett
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2022-05-09       Impact factor: 3.405

  4 in total