Literature DB >> 14524557

What price support? Ventricular assist device induced systemic response.

Larry O Thompson1, Matthias Loebe, George P Noon.   

Abstract

Use of ventricular support systems has been associated with myriad systemic complications. Engendered by the blood-biomaterial interface of a unique host/device relationship, these complications include diverse humoral dyscrasias that frequently culminate in episodes of bleeding, hemolysis and thrombogenicity, heightened susceptibility to inflammation and infection, and transient immunal compromise. Recent endeavor in biocompatibility research has served to illustrate the critical role played by cellular, humoral, and neurohormonal components in regulating cytokine expression and has provided insight into the complexities involved in such biomechanical juxtapositions. The following is intended as a review of current literature attempting to address the many aspects of this host/device interaction and their consequences for the supported patient.

Entities:  

Mesh:

Year:  2003        PMID: 14524557     DOI: 10.1097/01.mat.0000085672.42122.49

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  7 in total

Review 1.  The use of computational fluid dynamics in the development of ventricular assist devices.

Authors:  Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Eng Phys       Date:  2010-11-13       Impact factor: 2.242

2.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

3.  A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index.

Authors:  Katharine H Fraser; Tao Zhang; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  J Biomech Eng       Date:  2012-08       Impact factor: 2.097

4.  A numerical study of blood flow using mixture theory.

Authors:  Wei-Tao Wu; Nadine Aubry; Mehrdad Massoudi; Jeongho Kim; James F Antaki
Journal:  Int J Eng Sci       Date:  2014-03-01       Impact factor: 8.843

5.  Characterization of ventricular assist device-mediated sensitization in the bridge-to-heart-transplantation patient.

Authors:  Murray H Kwon; Jennifer Q Zhang; Joanna M Schaenman; Martin Cadeiras; David W Gjertson; Carolyn A Krystal; Hillel Laks; Abbas Ardehali; Mario C Deng; Richard J Shemin; Elaine F Reed
Journal:  J Thorac Cardiovasc Surg       Date:  2015-01-08       Impact factor: 5.209

6.  Platelet Mapping by Thromboelastography and Whole Blood Aggregometry in Adult Patients Supported by Mechanical Circulatory Support Device on Aspirin Therapy.

Authors:  Oksana Volod; Francisco A Arabia; Lee D Lam; Alice Runge; Caleb Cheng; Lawrence S C Czer
Journal:  J Extra Corpor Technol       Date:  2020-03

7.  Surface modification of a titanium alloy with a phospholipid polymer prepared by a plasma-induced grafting technique to improve surface thromboresistance.

Authors:  Sang Ho Ye; Carl A Johnson; Joshua R Woolley; Heung-Il Oh; Lara J Gamble; Kazuhiko Ishihara; William R Wagner
Journal:  Colloids Surf B Biointerfaces       Date:  2009-07-07       Impact factor: 5.268

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.