Literature DB >> 14523966

Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions.

M Markl1, R Bammer, M T Alley, C J Elkins, M T Draney, A Barnett, M E Moseley, G H Glover, N J Pelc.   

Abstract

To characterize gradient field nonuniformity and its effect on velocity encoding in phase contrast (PC) MRI, a generalized model that describes this phenomenon and enables the accurate reconstruction of velocities is presented. In addition to considerable geometric distortions, inhomogeneous gradient fields can introduce deviations from the nominal gradient strength and orientation, and therefore spatially-dependent first gradient moments. Resulting errors in the measured phase shifts used for velocity encoding can therefore cause significant deviations in velocity quantification. The true magnitude and direction of the underlying velocities can be recovered from the phase difference images by a generalized PC velocity reconstruction, which requires the acquisition of full three-directional velocity information. The generalized reconstruction of velocities is applied using a matrix formalism that includes relative gradient field deviations derived from a theoretical model of local gradient field nonuniformity. In addition, an approximate solution for the correction of one-directional velocity encoding is given. Depending on the spatial location of the velocity measurements, errors in velocity magnitude can be as high as 60%, while errors in the velocity encoding direction can be up to 45 degrees. Results of phantom measurements demonstrate that effects of gradient field nonuniformity on PC-MRI can be corrected with the proposed method.

Mesh:

Year:  2003        PMID: 14523966     DOI: 10.1002/mrm.10582

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  45 in total

Review 1.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

Review 2.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

3.  Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging.

Authors:  Roland Bammer; Thomas A Hope; Murat Aksoy; Marcus T Alley
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

Review 4.  [MR-based tridirectional flow imaging. Acquisition and 3D analysis of flows in the thoracic aorta].

Authors:  R Unterhinninghofen; S Ley; A Frydrychowicz; M Markl
Journal:  Radiologe       Date:  2007-11       Impact factor: 0.635

5.  Improved real-time tagged MRI using REALTAG.

Authors:  Weiyi Chen; Nam Gyun Lee; Dani Byrd; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

6.  Automatic correction of background phase offset in 4D-flow of great vessels and of the heart in MRI using a third-order surface model.

Authors:  Damian Craiem; Ariel F Pascaner; Mariano E Casciaro; Umit Gencer; Joaquin Alcibar; Gilles Soulat; Elie Mousseaux
Journal:  MAGMA       Date:  2019-06-22       Impact factor: 2.310

7.  UCEPR: Ultrafast localized CEST-spectroscopy with PRESS in phantoms and in vivo.

Authors:  Zheng Liu; Ivan E Dimitrov; Robert E Lenkinski; Asghar Hajibeigi; Elena Vinogradov
Journal:  Magn Reson Med       Date:  2015-05-29       Impact factor: 4.668

8.  Evaluation of valvular insufficiency and shunts with parallel-imaging compressed-sensing 4D phase-contrast MR imaging with stereoscopic 3D velocity-fusion volume-rendered visualization.

Authors:  Albert Hsiao; Michael Lustig; Marcus T Alley; Mark J Murphy; Shreyas S Vasanawala
Journal:  Radiology       Date:  2012-08-24       Impact factor: 11.105

9.  Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Authors:  Albert Hsiao; Ufra Yousaf; Marcus T Alley; Michael Lustig; Frandics Pak Chan; Beverley Newman; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

10.  Robust 4D flow denoising using divergence-free wavelet transform.

Authors:  Frank Ong; Martin Uecker; Umar Tariq; Albert Hsiao; Marcus T Alley; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.