Simulation of abdomen sonography. Evaluation of a new ultrasound simulator.

C Terkamp, G Kirchner, J Wedemeyer, A Dettmer, J Kielstein, H Reindell, J Bleck, M Manns, M Gebel.   

Abstract

AIM: We developed and evaluated a simulator for the sonography of the abdomen in order to improve the teaching quality in sonography training.
METHOD: Eleven medicine residents who had received 4 to 12 months full time sonography training performed ultrasound examinations of the right upper quadrant in 5 consecutive patients and in 5 simulator cases. The correctness of their findings and the time required for the examinations were measured. The subjective confidence in their findings and the handling of the ultrasound machines were rated on a visual analogue scale.
RESULTS: During patient ultrasound examination 75 % (SEM 9%) of all pathologic findings were recognized by the residents, whereas 71 % (SEM 8%) of the pathologies of the simulator cases were found. This minimal difference was not significant in the paired, two sided t-test (p = 0.15). Severe pathologies did not escape detection. The time required for patient examination(10.57 min, SEM 3.25 min) was not significantly different (p = 0.53) to the time required for the simulator cases (9.59 min, SEM 2.98 min). The subjective confidence in the sonographic findings did not differ significantly (p = 0.39) between the real patient situation (68%, SEM 6%) and the simulation (64%, SEM 12 %). Only the handling of the ultrasound machines was judged to be significantly better (p=0.008) than the simulator (74%,SEM 7% vs. 61 %, SEM 12%).
CONCLUSION: In this first direct crossover comparison between real patient sonography and simulator based scanning we proved that the simulator we developed simulates the real patient examination reliably and reproducibly.

Entities:  

Mesh:

Year:  2003        PMID: 14521149     DOI: 10.1055/s-2003-41713

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  5 in total

1.  [Diagnostic and interventional abdominal ultrasonography].

Authors:  A Potthoff; M J Gebel; K Rifai
Journal:  Internist (Berl)       Date:  2012-03       Impact factor: 0.743

2.  Improving realism in patient-specific abdominal ultrasound simulation using CycleGANs.

Authors:  Santiago Vitale; José Ignacio Orlando; Emmanuel Iarussi; Ignacio Larrabide
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-08-07       Impact factor: 2.924

3.  Abdominal ultrasound examination training using an ultrasound phantom and volume navigation system.

Authors:  Chizu Uetake; Akihiro Nakamoto; Toshikuni Suda; Masaya Tamano
Journal:  J Med Ultrason (2001)       Date:  2016-02-26       Impact factor: 1.314

4.  Recommendations on the Use of Ultrasound Guidance for Adult Abdominal Paracentesis: A Position Statement of the Society of Hospital Medicine.

Authors:  Joel Cho; Trevor P Jensen; Kreegan Reierson; Benji K Mathews; Anjali Bhagra; Ricardo Franco-Sadud; Loretta Grikis; Michael Mader; Ria Dancel; Brian P Lucas; Nilam J Soni
Journal:  J Hosp Med       Date:  2019-01-02       Impact factor: 2.960

5.  Fast and automatic ultrasound simulation from CT images.

Authors:  Weijian Cong; Jian Yang; Yue Liu; Yongtian Wang
Journal:  Comput Math Methods Med       Date:  2013-11-18       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.