Literature DB >> 14516537

Image Fusion System Using PACS for MRI, CT, and PET Images.

Saleh Alyafei1, Tomio Inoue, Hong Zhang, Khalil Ahmed, Noboru Oriuchi, Noriko Sato, Hideki Suzuki, Keigo Endo.   

Abstract

This paper presents and evaluates Picture Archiving and Communication System (PACS) and its interaction with the image fusion applications using positron emission tomography (PET), CT, and MRI, as well as some clinical applications of fusion images. A network connections between medium-sized PACS involving CT, MRI, SPECT, and PET were developed. Image registration and fusion was achieved in the PET's workstation by Advanced Visual System (AVS) software. Reconstructed datasets of CT, MRI, SPECT, and PET were transferred and archived in PACS servers. Series of anatomical images of CT and MRI were fused with metabolical images of PET with (18)F labeled fluoro-2-deoxy-D-glucose (FDG). Throughput rate of image data, as well as clinical applications of fusion images were evaluated and correlated with phantom studies. The average throughput rate of archiving and processing steps was 0.45 Mbps, 0.77 Mbps, respectively. Image fusion experiment using phantom and patients' data showed high accuracy in all directions. The combination of PACS and image fusion provided very useful clinical tools and made it quite easy to maximize the benefit from the diagnostic imaging.

Entities:  

Year:  1999        PMID: 14516537     DOI: 10.1016/s1095-0397(99)00018-7

Source DB:  PubMed          Journal:  Clin Positron Imaging        ISSN: 1095-0397


  8 in total

1.  [Combined Scanners (PET/CT, SPECT/CT) Versus Multimodality Imaging with Separated Systems].

Authors:  T Pfluger; C la Fougère; J Stauss; R Santos; C Vollmar; K Hahn
Journal:  Radiologe       Date:  2004-11       Impact factor: 0.635

2.  Sliced alternating DICOM series: convenient visualisation of image fusion on PACS.

Authors:  Wouter V Vogel; Jorn A van Dalen; Henkjan Huisman; Wim J G Oyen; Nico Karssemeijer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-02       Impact factor: 9.236

3.  PET/CT fusion viewing software for use with picture archiving and communication systems.

Authors:  Ki Chun Im; Ik Soo Choi; Jin-Sook Ryu; Gi Seoung Eo; Jae Seung Kim; Dae Hyuk Moon
Journal:  J Digit Imaging       Date:  2009-08-06       Impact factor: 4.056

4.  Surgical technique: Computer-generated custom jigs improve accuracy of wide resection of bone tumors.

Authors:  Fazel A Khan; Joseph D Lipman; Andrew D Pearle; Patrick J Boland; John H Healey
Journal:  Clin Orthop Relat Res       Date:  2013-01-05       Impact factor: 4.176

Review 5.  Role and cost effectiveness of PET/CT in management of patients with cancer.

Authors:  Muhammad Wasif Saif; Ifigenia Tzannou; Nektaria Makrilia; Kostas Syrigos
Journal:  Yale J Biol Med       Date:  2010-06

6.  Haptic robot-assisted surgery improves accuracy of wide resection of bone tumors: a pilot study.

Authors:  Fazel Khan; Andrew Pearle; Christopher Lightcap; Patrick J Boland; John H Healey
Journal:  Clin Orthop Relat Res       Date:  2013-03       Impact factor: 4.176

Review 7.  Multi-modality nuclear medicine imaging: artefacts, pitfalls and recommendations.

Authors:  Jorn A van Dalen; Wouter V Vogel; Frans H M Corstens; Wim J G Oyen
Journal:  Cancer Imaging       Date:  2007-05-28       Impact factor: 3.909

8.  Perfusion and diffusion MRI combined with ¹¹C-methionine PET in the preoperative evaluation of suspected adult low-grade gliomas.

Authors:  Shala Ghaderi Berntsson; Anna Falk; Irina Savitcheva; Andrea Godau; Maria Zetterling; Göran Hesselager; Irina Alafuzoff; Elna-Marie Larsson; Anja Smits
Journal:  J Neurooncol       Date:  2013-06-16       Impact factor: 4.130

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.