Literature DB >> 14514097

Polarization-maintaining fiber-based optical low-coherence reflectometer for characterization and ranging of birefringence.

Digant P Davé1, Taner Akkin, Thomas E Milner.   

Abstract

We describe a polarization-maintaining fiber-based polarization-sensitive optical low-coherence reflectometer for measurement of depth-resolved birefringence. Unlike for other fiber-based polarization-sensitive optical low-coherence reflectometers, here the linear birefringence of a sample can be measured from data recorded in a single A scan. Simultaneous measurement of retardation and orientation of birefringent axes with mica wave plates is demonstrated. The measured retardation is insensitive to sample rotation in the plane perpendicular to ranging.

Entities:  

Mesh:

Year:  2003        PMID: 14514097     DOI: 10.1364/ol.28.001775

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  9 in total

1.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

2.  Quantitative single-mode fiber based PS-OCT with single input polarization state using Mueller matrix.

Authors:  Zhenyang Ding; Chia-Pin Liang; Qinggong Tang; Yu Chen
Journal:  Biomed Opt Express       Date:  2015-04-22       Impact factor: 3.732

3.  Single input state, single-mode fiber-based polarization-sensitive optical frequency domain imaging by eigenpolarization referencing.

Authors:  Norman Lippok; Martin Villiger; Changsu Jun; Brett E Bouma
Journal:  Opt Lett       Date:  2015-05-01       Impact factor: 3.776

4.  Degradation in the degree of polarization in human retinal nerve fiber layer.

Authors:  Biwei Yin; Bingqing Wang; Henry G Rylander; Thomas E Milner
Journal:  J Biomed Opt       Date:  2014-01       Impact factor: 3.170

5.  Real-time polarization-sensitive optical coherence tomography data processing with parallel computing.

Authors:  Gangjun Liu; Jun Zhang; Lingfeng Yu; Tuqiang Xie; Zhongping Chen
Journal:  Appl Opt       Date:  2009-11-10       Impact factor: 1.980

6.  Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography.

Authors:  Erich Götzinger; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2009-12-07       Impact factor: 3.894

7.  High-speed polarization sensitive optical coherence tomography scan engine based on Fourier domain mode locked laser.

Authors:  Marco Bonesi; Harald Sattmann; Teresa Torzicky; Stefan Zotter; Bernhard Baumann; Michael Pircher; Erich Götzinger; Christoph Eigenwillig; Wolfgang Wieser; Robert Huber; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2012-10-25       Impact factor: 3.732

8.  Birefringence measurement of the retinal nerve fiber layer by swept source polarization sensitive optical coherence tomography.

Authors:  Badr Elmaanaoui; Bingqing Wang; Jordan C Dwelle; Austin B McElroy; Shuang S Liu; Henry G Rylander; Thomas E Milner
Journal:  Opt Express       Date:  2011-05-23       Impact factor: 3.894

9.  Single input state polarization sensitive swept source optical coherence tomography based on an all single mode fiber interferometer.

Authors:  Wolfgang Trasischker; Stefan Zotter; Teresa Torzicky; Bernhard Baumann; Richard Haindl; Michael Pircher; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2014-07-28       Impact factor: 3.732

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.