Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation.

Todd D Stewart1, Joanne L Tipper, Gerard Insley, Robert M Streicher, Eileen Ingham, John Fisher.   

Abstract

The wear of zirconia femoral heads against alumina acetabular inserts with swing-phase microseparation was investigated in a hip joint simulator. Under mild microseparation conditions, the wear was very low, with an average wear rate of 0.05 mm(3)/million cycles reported over 5 million cycles of testing. However, under severe microseparation conditions representative of greater joint laxity, the wear rate of zirconia against alumina increased by 2 orders of magnitude, producing severe wear and, in one case, femoral head fracture. The adverse results of this study indicate that the combination of a zirconia femoral head articulating against an alumina acetabular insert is not recommended for clinical use. The results further raise concerns over the suitability of conventional simulators in evaluating the wear of ceramic hip prostheses.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14513445     DOI: 10.1016/s0883-5403(03)00204-3

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings.

Authors:  J C Keurentjes; R M Kuipers; D J Wever; B W Schreurs
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

2.  Do obesity and/or stripe wear increase ceramic liner fracture risk? An XFEM analysis.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

3.  Osteogenesis ability of CAD/CAM porous zirconia scaffolds enriched with nano-hydroxyapatite particles.

Authors:  Moustafa N Aboushelib; Rehab Shawky
Journal:  Int J Implant Dent       Date:  2017-05-19

4.  An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements.

Authors:  O O'Dwyer Lancaster-Jones; S Williams; L M Jennings; J Thompson; G H Isaac; J Fisher; M Al-Hajjar
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-09-23       Impact factor: 3.368

5.  Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions.

Authors:  Mazen Al-Hajjar; John Fisher; Sophie Williams; Joanne L Tipper; Louise M Jennings
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-12-20       Impact factor: 3.368

6.  Wear of composite ceramics in mixed-material combinations in total hip replacement under adverse edge loading conditions.

Authors:  Mazen Al-Hajjar; Silvia Carbone; Louise M Jennings; Sabine Begand; Thomas Oberbach; Daniel Delfosse; John Fisher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-04-08       Impact factor: 3.368

7.  Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints.

Authors:  Feng Liu; John Fisher
Journal:  Tribol Int       Date:  2017-09       Impact factor: 4.872

8.  Early low complication rate of ceramic-on-ceramic total hip arthroplasty by direct anterior approach.

Authors:  Paul Henri Bauwens; Camdon Fary; Elvire Servien; Sébastien Lustig; Cécile Batailler
Journal:  SICOT J       Date:  2020-08-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.