Piezoelectric sensor determination of arterial pulse wave velocity.

J McLaughlin1, M McNeill, B Braun, P D McCormack.   

Abstract

Arterial pulse wave velocity (APWV) is a measure of the elasticity (or stiffness) of peripheral arterial blood vessels. The pulse referred to here will be the pressure pulse as opposed to the flow pulse measured by ultrasound Doppler. The pressure pulse velocity varies over the range from about 12 m s(-1) to 15 m s(-1) in stiff peripheral arteries, whereas in normal arteries it has a velocity in the range of 7 to 9 m s(-1). The aim of this project was the development of a fast and easy to use system for the determination of peripheral arterial pulse wave velocity. The principle of the PWV measurement is based on simultaneous measurement of two pulse waves at two different positions, such as the radial artery at the wrist and the brachial artery just above the elbow. By determining the pulse transit time between these points and the distance measured between the two locations, pulse wave velocity may then be calculated. The pressure pulse detection is done by using two piezoelectric sensors which generate a measurable voltage at the output contacts if they are mechanically deformed. The deformation produced voltage is first amplified and filtered and then digitalized with a data acquisition card. The analysis of the data obtained from the sensors includes a filtering process, the calculation of the PWV with three different methods--foot-to-foot, cross-correlation and peak-to-peak-and the determination of the arterial pulse rate. Extensive measurements with human test subjects were carried out to optimize the techniques of data acquisition and analysis. For example, it was found that the best procedure was to hold the sensors in place using elastic straps alone. The data analysis was upgraded with an additional software module, which deletes, in effect, outriders or invalid measurements. With the optimized system, a series involving eight test subjects ranging in age from 22 to 32 years was completed (all normotensive). The arterial pulse wave velocities determined covered a range from 6 m s(-1) to 12 m s(-1), with an average standard deviation of less than 2.5 m s(-1) for individual results. These are slightly higher, but close to published APWV data. The results showed that reproducible results can be obtained with the existing PWV acquirement and analysis system.

Entities:  

Mesh:

Year:  2003        PMID: 14509307     DOI: 10.1088/0967-3334/24/3/306

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  15 in total

1.  A novel method for artery detection in laparoscopic surgery.

Authors:  Hamed Akbari; Yukio Kosugi; Kazunori Kihara
Journal:  Surg Endosc       Date:  2007-12-20       Impact factor: 4.584

2.  Pulse transit time based on piezoelectric technique at the radial artery.

Authors:  Jong Yong Abdiel Foo; Chu Sing Lim
Journal:  J Clin Monit Comput       Date:  2006-05-16       Impact factor: 2.502

3.  A comparative study of photoplethysmogram and piezoelectric plethysmogram signals.

Authors:  Qasem Qananwah; Ahmad Dagamseh; Hiam Alquran; Khalid Shaker Ibrahim; Moh'd Alodat; Oliver Hayden
Journal:  Phys Eng Sci Med       Date:  2020-08-31

4.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

5.  An innovative piezoelectric-based method for measuring pulse wave velocity in patients with hypertension.

Authors:  John C Murphy; Katherine Morrison; James McLaughlin; Ganesh Manoharan; Aa Jennifer Adgey
Journal:  J Clin Hypertens (Greenwich)       Date:  2011-03-04       Impact factor: 3.738

6.  Development of a radial pulse tonometric (RPT) sensor with a temperature compensation mechanism.

Authors:  Seong-Ki Yoo; Ki-Young Shin; Tae-Bum Lee; Seung-Oh Jin; Jaeuk U Kim
Journal:  Sensors (Basel)       Date:  2013-01-04       Impact factor: 3.576

7.  The effect of acute aerobic exercise on pulse wave velocity and oxidative stress following postprandial hypertriglyceridemia in healthy men.

Authors:  Conor M Mc Clean; Jim Mc Laughlin; George Burke; Marie H Murphy; Tom Trinick; Ellie Duly; Gareth W Davison
Journal:  Eur J Appl Physiol       Date:  2007-02-24       Impact factor: 3.346

8.  Flexible PZT thin film tactile sensor for biomedical monitoring.

Authors:  Hong-Jie Tseng; Wei-Cheng Tian; Wen-Jong Wu
Journal:  Sensors (Basel)       Date:  2013-04-25       Impact factor: 3.576

9.  Quantitative analysis of sensor for pressure waveform measurement.

Authors:  Shing-Hong Liu; Chu-Chang Tyan
Journal:  Biomed Eng Online       Date:  2010-01-21       Impact factor: 2.819

10.  Exercise and postprandial lipaemia: effects on peripheral vascular function, oxidative stress and gastrointestinal transit.

Authors:  Miriam Clegg; Conor McClean; W Gareth Davison; H Marie Murphy; Tom Trinick; Ellie Duly; Jim McLaughlin; Mark Fogarty; Amir Shafat
Journal:  Lipids Health Dis       Date:  2007-10-31       Impact factor: 3.876

View more