Literature DB >> 14508310

Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil.

Michel M R F Struys1, Hugo Vereecke, Annelies Moerman, Erik Weber Jensen, David Verhaeghen, Nicolaas De Neve, Frank J E Dumortier, Eric P Mortier.   

Abstract

BACKGROUND: This study was conducted to compare the performance accuracy of the independent variables Bispectral Index (BIS), A-Line ARX index (AAI), and predicted propofol effect-site concentration (CePROP) to measure the dependent variables of loss of responses to different stimulation defined as loss of response to verbal command (LORverbal), eyelash reflex (LORlash), and noxious stimulus (LORnoxious) during stepwise increased levels of propofol infusion with and without remifentanil.
METHODS: Forty-five patients were randomly allocated to one of three groups (0, 2, and 4 ng/ml remifentanil) to receive graded CePROP and predicted effect compartment controlled remifentanil (CeREMI). At every step, the ability to respond to verbal command using the Observer's Assessment of Alertness/Sedation Scale (OAA/S), eyelash reflex, and electrical tetanic noxious stimulus were compared against BIS, AAI, and CePROP. Prediction probability and sensitivity/specificity were calculated.
RESULTS: Increasing CeREMI increased BIS and AAI values at LORverbal and LORlash and decreased CePROP. Similar findings were found for LORnoxious. The overall prediction probability to measure the hypnotic component of anesthesia remained accurate in the three groups for BIS, AAI, and CePROP. Combined information from CePROP, CeREMI, and BIS or AAI increased the overall prediction probability for predicting the OAA/S scale and LORlash. Less accuracy to LORnoxious was found in all independent variables.
CONCLUSIONS: Although BIS, AAI, and CePROP were influenced by remifentanil during propofol administration, their ability to detect OAA/S and LORlash remained accurate. Improved performance is obtained when BIS and AAI are measured in conjunction with drug targeted effect-site concentrations. Remifentanil decreases the ability of these independent variables to detect LORnoxious.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14508310     DOI: 10.1097/00000542-200310000-00010

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  16 in total

Review 1.  A critique of ancillary tests for brain death.

Authors:  G Bryan Young; Donald Lee
Journal:  Neurocrit Care       Date:  2004       Impact factor: 3.210

2.  Comparison of electrophysiologic monitors with clinical assessment of level of sedation.

Authors:  Christopher J Chisholm; Joseph Zurica; Dmitry Mironov; Robert R Sciacca; Eugene Ornstein; Eric J Heyer
Journal:  Mayo Clin Proc       Date:  2006-01       Impact factor: 7.616

Review 3.  [Measurement of the depth of anaesthesia].

Authors:  G N Schmidt; J Müller; P Bischoff
Journal:  Anaesthesist       Date:  2008-01       Impact factor: 1.041

4.  Variation of bispectral index under TIVA with propofol in a paediatric population.

Authors:  O Tirel; E Wodey; R Harris; J Y Bansard; C Ecoffey; L Senhadji
Journal:  Br J Anaesth       Date:  2008-01       Impact factor: 9.166

5.  Lessons learned from closed loops in engineering: towards a multivariable approach regulating depth of anaesthesia.

Authors:  Clara M Ionescu; Ioana Nascu; Robin De Keyser
Journal:  J Clin Monit Comput       Date:  2013-11-23       Impact factor: 2.502

6.  An enriched simulation environment for evaluation of closed-loop anesthesia.

Authors:  Mengqi Fang; Yuan Tao; Youqing Wang
Journal:  J Clin Monit Comput       Date:  2013-06-08       Impact factor: 2.502

7.  Cerebral monitoring in the operating room and the intensive care unit: an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part I: The electroencephalogram.

Authors:  Enno Freye; Joseph V Levy
Journal:  J Clin Monit Comput       Date:  2005-04       Impact factor: 2.502

8.  Frequency and clinical impact of preserved bispectral index activity during deep sedation in mechanically ventilated ICU patients.

Authors:  Pierre Trouiller; Pascal Fangio; Catherine Paugam-Burtz; Corinne Appéré-de-Vecchi; Paul Merckx; Nicolas Louvet; Sebastian Pease; Hervé Outin; Jean Mantz; Bernard De Jonghe
Journal:  Intensive Care Med       Date:  2009-09-15       Impact factor: 17.440

9.  Spectral entropy as a monitor of depth of propofol induced sedation.

Authors:  Padraig Mahon; Robert G Kowalski; Anthony P Fitzgerald; Elaine M Lynch; Geraldine B Boylan; Brian McNamara; George D Shorten
Journal:  J Clin Monit Comput       Date:  2008-02-06       Impact factor: 2.502

10.  Influence of Sliding Time Window Size Selection Based on Heart Rate Variability Signal Analysis on Intelligent Monitoring of Noxious Stimulation under Anesthesia.

Authors:  Qiang Yin; Dai Shen; Qian Ding
Journal:  Neural Plast       Date:  2021-06-05       Impact factor: 3.599

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.