Literature DB >> 1450476

Accuracy of intravenous infusion pumps in continuous renal replacement therapies.

R Jenkins1, H Harrison, B Chen, D Arnold, J Funk.   

Abstract

Most extracorporeal continuous renal replacement therapies (CRRT) require inflow pumping of either dialysate, filtrate replacement solution, or both. Outflow of spent dialysate and ultrafiltrate can be accomplished by gravity drainage or pump. Intravenous infusion pumps have been commonly used for these purposes, although little is known about the accuracy of these pumps. To evaluate accuracy of two different types of intravenous infusion pumps used in CRRT, we studied flow rates at nine different pressure variations in three piston type and three linear peristaltic pumps. The results showed that error of either pump was not different for flow rates of 4 and 16 ml/min. Both types of pumps were affected by fluid circuit pressures, although pressure conditions under which error was low were different for each pump type. The linear peristaltic pumps were most accurate under conditions of low pump inlet pressure, whereas piston pumps were most accurate under conditions of low pump pressure gradient (outlet minus inlet) of 0 or -100 mmHg. The magnitude of error outside these conditions was substantial, reaching 12.5% for the linear peristaltic pump when inlet pressure was -100 mmHg and outlet pressure was 100 mmHg. Error may be minimized in the clinical setting by choosing the pump type best suited for the pressure conditions expected for the renal replacement modality in use.

Mesh:

Year:  1992        PMID: 1450476

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  A machine for haemodialysing very small infants.

Authors:  Nicholas L Everdell; Malcolm G Coulthard; Jean Crosier; Michael J Keir
Journal:  Pediatr Nephrol       Date:  2005-03-17       Impact factor: 3.714

2.  Enhanced fluid management with continuous venovenous hemofiltration in pediatric respiratory failure patients receiving extracorporeal membrane oxygenation support.

Authors:  Nancy G Hoover; Michael Heard; Christopher Reid; Scott Wagoner; Kristine Rogers; Jason Foland; Matthew L Paden; James D Fortenberry
Journal:  Intensive Care Med       Date:  2008-07-15       Impact factor: 17.440

Review 3.  Continuous arterial-venous diahemofiltration and continuous veno-venous diahemofiltration in infants and children.

Authors:  T E Bunchman; R A Donckerwolcke
Journal:  Pediatr Nephrol       Date:  1994-02       Impact factor: 3.714

Review 4.  A review of continuous renal replacement therapy.

Authors:  C G Flynn
Journal:  Ir J Med Sci       Date:  1994-07       Impact factor: 1.568

Review 5.  Adjunctive Therapies During Extracorporeal Membrane Oxygenation to Enhance Multiple Organ Support in Critically Ill Children.

Authors:  Marguerite Orsi Canter; Jessica Daniels; Brian C Bridges
Journal:  Front Pediatr       Date:  2018-04-03       Impact factor: 3.418

6.  Using additional pressure control lines when connecting a continuous renal replacement therapy device to an extracorporeal membrane oxygenation circuit.

Authors:  Soo Jin Na; Hee Jung Choi; Chi Ryang Chung; Yang Hyun Cho; Hye Ryoun Jang; Gee Young Suh; Kyeongman Jeon
Journal:  BMC Nephrol       Date:  2018-12-19       Impact factor: 2.388

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.