Literature DB >> 15772838

A machine for haemodialysing very small infants.

Nicholas L Everdell1, Malcolm G Coulthard, Jean Crosier, Michael J Keir.   

Abstract

Babies weighing under 6 kg are difficult to dialyse, especially those as small as 1 kg. Peritoneal dialysis is easier than haemodialysis, but is not always possible, and clears molecules less efficiently. Two factors complicate haemodialysis. First, extracorporeal circuits are large relative to a baby's blood volume, necessitating priming with fresh or modified blood. Second, blood flow from infants' access vessels is disproportionately low (Poiseuille's law), causing inadequate dialysis, or clotting within the circuit. These problems are minimised by using single lumen access, a very small circuit, and a reservoir syringe to separate the sampling and dialyser blood flow rates. Its manual operation is tedious, so we developed a computer-controlled, pressure-monitored machine to run it, including adjusting the blood withdrawal rate from poorly sampling lines. We have dialysed four babies weighing 0.8-3.4 kg, with renal failure or metabolic disorders. The circuits did not require priming. Clearances of creatinine, urea, potassium, phosphate and ammonia were mean (SD) 0.54 (0.22) ml/min using one dialyser, and 0.98 (0.22) ml/min using two in parallel. Ammonia clearance in a 2.4 kg baby had a 9 h half-life. Ultrafiltration up to 45 ml/h was achieved easily. This device provided infants with immediate, effective and convenient haemodialysis, typically delivered for prolonged periods.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15772838     DOI: 10.1007/s00467-004-1785-5

Source DB:  PubMed          Journal:  Pediatr Nephrol        ISSN: 0931-041X            Impact factor:   3.714


  12 in total

1.  Haemodialysing infants: theoretical limitations, and single versus double lumen lines.

Authors:  M G Coulthard; J Sharp
Journal:  Pediatr Nephrol       Date:  2001-04       Impact factor: 3.714

2.  Errors in fluid balance with pump control of continuous hemodialysis.

Authors:  M Roberts; R J Winney
Journal:  Int J Artif Organs       Date:  1992-02       Impact factor: 1.595

3.  Haemodialysis and ultrafiltration in babies weighing under 1000 g.

Authors:  M G Coulthard; J Sharp
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-11       Impact factor: 5.747

Review 4.  Managing acute renal failure in very low birthweight infants.

Authors:  M G Coulthard; B Vernon
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-11       Impact factor: 5.747

5.  Comparison of a new and a standard single-needle dialysis system using a mathematical model.

Authors:  D De Wachter; P Verdonck; R Verhoeven; R Hombrouckx
Journal:  Artif Organs       Date:  1993-05       Impact factor: 3.094

6.  Hemodialysis in the premature infant.

Authors:  G H Bock; A Campos; T Thompson; S M Maher; C M Kjellstrand
Journal:  Am J Dis Child       Date:  1981-02

7.  Maturation of glomerular filtration in preterm and mature babies.

Authors:  M G Coulthard
Journal:  Early Hum Dev       Date:  1985-09       Impact factor: 2.079

8.  A new single needle dialysis system.

Authors:  G De Virgiliis; M Vanin; U Buoncristiani
Journal:  Trans Am Soc Artif Intern Organs       Date:  1985

9.  Dialysis in neonates with inborn errors of metabolism.

Authors:  F Schaefer; E Straube; J Oh; O Mehls; E Mayatepek
Journal:  Nephrol Dial Transplant       Date:  1999-04       Impact factor: 5.992

10.  Pre dialysis of blood prime in continuous hemodialysis normalizes pH and electrolytes.

Authors:  Deborah A Pasko; Theresa A Mottes; Bruce A Mueller
Journal:  Pediatr Nephrol       Date:  2003-10-02       Impact factor: 3.714

View more
  7 in total

1.  Report of an NIH task force on research priorities in chronic kidney disease in children.

Authors:  Russell W Chesney; Eileen Brewer; Marva Moxey-Mims; Sandra Watkins; Susan L Furth; William E Harmon; Richard N Fine; Ronald J Portman; Bradley A Warady; Isidro B Salusky; Craig B Langman; Debbie Gipson; Peter Scheidt; Harold Feldman; Frederick J Kaskel; Norman J Siegel
Journal:  Pediatr Nephrol       Date:  2005-10-27       Impact factor: 3.714

Review 2.  The Role of RRT in Hyperammonemic Patients.

Authors:  Shruti Gupta; Andrew Z Fenves; Robert Hootkins
Journal:  Clin J Am Soc Nephrol       Date:  2016-05-19       Impact factor: 8.237

3.  Ability of a novel system for neonatal extracorporeal renal replacement therapy with an ultra-small volume circuit to remove solutes in vitro.

Authors:  Saeko Nishimi; Ken Ishikawa; Makoto Sasaki; Hiromi Furukawa; Akira Takada; Shoichi Chida
Journal:  Pediatr Nephrol       Date:  2015-10-22       Impact factor: 3.714

4.  Haemodialysing babies weighing <8 kg with the Newcastle infant dialysis and ultrafiltration system (Nidus): comparison with peritoneal and conventional haemodialysis.

Authors:  Malcolm G Coulthard; Jean Crosier; Clive Griffiths; Jon Smith; Michael Drinnan; Mike Whitaker; Robert Beckwith; John N S Matthews; Paul Flecknell; Heather J Lambert
Journal:  Pediatr Nephrol       Date:  2014-08-15       Impact factor: 3.714

5.  Responses to vocalizations and auditory controls in the human newborn brain.

Authors:  Alejandrina Cristia; Yasuyo Minagawa; Emmanuel Dupoux
Journal:  PLoS One       Date:  2014-12-17       Impact factor: 3.240

6.  I-KID study protocol: evaluation of efficacy, outcomes and safety of a new infant haemodialysis and ultrafiltration machine in clinical use: a randomised clinical investigation using a cluster stepped-wedge design.

Authors:  Heather J Lambert; Shriya Sharma; John N S Matthews
Journal:  BMJ Paediatr Open       Date:  2021-10-18

7.  Towards an Algorithm-Based Tailored Treatment of Acute Neonatal Hyperammonemia.

Authors:  Sunny Eloot; Jonathan De Rudder; Patrick Verloo; Evelyn Dhont; Ann Raes; Wim Van Biesen; Evelien Snauwaert
Journal:  Toxins (Basel)       Date:  2021-07-13       Impact factor: 4.546

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.