Literature DB >> 1450425

Optical evaluation of red blood cell geometry using micropipette aspiration.

K G Engström1, B Möller, H J Meiselman.   

Abstract

Although red blood cell (RBC) geometry has been extensively studied by micropipette aspiration, the small size of RBC and pipettes vs. the optical resolution of light microscopy suggests the need to consider potential errors. The present study addressed such difficulties and investigated four specific problems: (1) use of exact equations to calculate RBC membrane area and volume; (2) calibration of the pipette internal diameter (PID); (3) correction for a noncylindrical pipette barrel; (4) diffraction distortion of the RBC image. The observed PID represents a cylinder lens enlargement that can be theoretically derived from the glass/buffer refractive index ratio (1.49/1.33 = 1.12). This enlargement was experimentally confirmed by: (1) studying pipettes bent to allow measurement through the barrel (horizontal) and at the orifice (vertical), with a resulting diameter ratio of 1.12 +/- 0.01; (2) and by replacing the surrounding buffer with immersion oil and hence abolishing the lens phenomenon (ratio = 1.12 +/- 0.02). In addition, use of aspirated oil droplets demonstrated a 3.2 +/- 0.2% error when the PID is focused at a sharp, maximum diameter. The average pipette cone angle was 1.49 +/- 0.09 degrees and varied considerably with pipette pulling procedures; calculated tongue geometry inside the pipette was affected by the noncylindrical pipette barrel. The RBC diffraction error, demonstrated by touching two aspirated cells held by opposing pipettes, was 0.091 +/- 0.002 microns. The PID, cone angle, and diffraction artifacts significantly (p < 0.001) affected calculated RBC geometry (average errors up to 5.4% for area and 9.6% for volume). Two new methods to calculate, rather than directly measure, the PID from images of a single RBC, during either osmotic or pressure manipulation, were evaluated; the osmotic method closely predicted the PID, whereas the pressure method markedly underestimated the PID. Our results thus confirm the need to consider the above-mentioned phenomena when determining RBC geometric parameters via micropipette aspiration.

Entities:  

Mesh:

Year:  1992        PMID: 1450425

Source DB:  PubMed          Journal:  Blood Cells        ISSN: 0340-4684


  9 in total

1.  Hyperosmotically induced volume change and calcium signaling in intervertebral disk cells: the role of the actin cytoskeleton.

Authors:  Scott Pritchard; Geoffrey R Erickson; Farshid Guilak
Journal:  Biophys J       Date:  2002-11       Impact factor: 4.033

2.  Measurement of inherent particle properties by dynamic light scattering: introducing electrorotational light scattering.

Authors:  B Prüger; P Eppmann; E Donath; J Gimsa
Journal:  Biophys J       Date:  1997-03       Impact factor: 4.033

3.  Hemoglobin senses body temperature.

Authors:  G M Artmann; Ilya Digel; K F Zerlin; Ch Maggakis-Kelemen; Pt Linder; D Porst; P Kayser; A M Stadler; G Dikta; A Temiz Artmann
Journal:  Eur Biophys J       Date:  2009-02-24       Impact factor: 1.733

4.  A direct micropipette-based calibration method for atomic force microscope cantilevers.

Authors:  Baoyu Liu; Yan Yu; Da-Kang Yao; Jin-Yu Shao
Journal:  Rev Sci Instrum       Date:  2009-06       Impact factor: 1.523

5.  A unified resistor-capacitor model for impedance, dielectrophoresis, electrorotation, and induced transmembrane potential.

Authors:  J Gimsa; D Wachner
Journal:  Biophys J       Date:  1998-08       Impact factor: 4.033

6.  Micropipette aspiration on the outer hair cell lateral wall.

Authors:  P S Sit; A A Spector; A J Lue; A S Popel; W E Brownell
Journal:  Biophys J       Date:  1997-06       Impact factor: 4.033

7.  Dielectric spectroscopy of human erythrocytes: investigations under the influence of nystatin.

Authors:  J Gimsa; T Schnelle; G Zechel; R Glaser
Journal:  Biophys J       Date:  1994-04       Impact factor: 4.033

8.  Single-shot full-field reflection phase microscopy.

Authors:  Zahid Yaqoob; Toyohiko Yamauchi; Wonshik Choi; Dan Fu; Ramachandra R Dasari; Michael S Feld
Journal:  Opt Express       Date:  2011-04-11       Impact factor: 3.894

9.  Numerical and experimental study on the development of electric sensor as for measurement of red blood cell deformability in microchannels.

Authors:  Kazuya Tatsumi; Yoichi Katsumoto; Ryoji Fujiwara; Kazuyoshi Nakabe
Journal:  Sensors (Basel)       Date:  2012-08-03       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.