Literature DB >> 14499295

The dependence of the elastic properties of osteoporotic cancellous bone on volume fraction and fabric.

Jasper Homminga1, Barbara R Mccreadie, Harrie Weinans, Rik Huiskes.   

Abstract

Osteoporosis is a progressive systemic skeletal condition characterized by low bone mass and microarchitectural deterioration, with a consequent increase in susceptibility to fracture. Hence, osteoporosis would be best diagnosed by in vivo measurements of bone strength. As this is not clinically feasible, our goal is to estimate bone strength through the assessment of elastic properties, which are highly correlated to strength. Previously established relations between morphological parameters (volume fraction and fabric) and elastic constants could be applied to estimate cancellous bone stiffness in vivo. However, these relations were determined for normal cancellous bone. Cancellous bone from osteoporotic patients may require different relations. In this study we set out to answer two questions. First, can the elastic properties of osteoporotic cancellous bone be estimated from morphological parameters? Second, do the relations between morphological parameters and elastic constants, determined for normal bone, apply to osteoporotic bone as well? To answer these questions we used cancellous bone cubes from femoral heads of patients with (n=26) and without (n=32) hip fractures. The elastic properties of the cubes were determined using micro-finite element analysis, assuming equal tissue moduli for all specimens. The morphological parameters were determined using microcomputed tomography. Our results showed that, for equal tissue properties, the elastic properties of cancellous bone from fracture patients could indeed be estimated from morphological parameters. The morphology-based relations used to estimate the elastic properties of cancellous bone are not different for women with or without fractures.

Entities:  

Mesh:

Year:  2003        PMID: 14499295     DOI: 10.1016/s0021-9290(03)00125-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  19 in total

1.  Predicting trabecular bone elastic properties from measures of bone volume fraction and fabric on the basis of micromagnetic resonance images.

Authors:  Michael J Wald; Jeremy F Magland; Chamith S Rajapakse; Yusuf A Bhagat; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

2.  Number crunching: how and when will numerical models be used in the clinical setting?

Authors:  W Brent Edwards; Karen L Troy
Journal:  Curr Osteoporos Rep       Date:  2011-03       Impact factor: 5.096

Review 3.  Trabecular bone failure at the microstructural level.

Authors:  Ralph Müller; G Harry van Lenthe
Journal:  Curr Osteoporos Rep       Date:  2006-06       Impact factor: 5.096

4.  Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site.

Authors:  Grant Bevill; Sarah K Easley; Tony M Keaveny
Journal:  J Biomech       Date:  2007-07-19       Impact factor: 2.712

5.  Quantitative, structural, and image-based mechanical analysis of nonunion fracture repaired by genetically engineered mesenchymal stem cells.

Authors:  Ilan Kallai; G Harry van Lenthe; Davide Ruffoni; Yoram Zilberman; Ralph Müller; Gadi Pelled; Dan Gazit
Journal:  J Biomech       Date:  2010-05-14       Impact factor: 2.712

6.  Finite element analysis of idealised unit cell cancellous structure based on morphological indices of cancellous bone.

Authors:  Mohammed Rafiq Abdul Kadir; Ardiyansyah Syahrom; Andreas Ochsner
Journal:  Med Biol Eng Comput       Date:  2010-03-12       Impact factor: 2.602

7.  Sparseness of the trabecular pattern on dental radiographs: visual assessment compared with semi-automated measurements.

Authors:  W G M Geraets; C Lindh; H Verheij
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

8.  Mechanical and microarchitectural analyses of cancellous bone through experiment and computer simulation.

Authors:  Ardiyansyah Syahrom; Mohammed Rafiq Abdul Kadir; Jaafar Abdullah; Andreas Öchsner
Journal:  Med Biol Eng Comput       Date:  2011-09-24       Impact factor: 2.602

9.  Improved fracture risk assessment based on nonlinear micro-finite element simulations from HRpQCT images at the distal radius.

Authors:  David Christen; L Joseph Melton; Alexander Zwahlen; Shreyasee Amin; Sundeep Khosla; Ralph Müller
Journal:  J Bone Miner Res       Date:  2013-12       Impact factor: 6.741

10.  Parametric analysis of orthopedic screws in relation to bone density.

Authors:  Elisabetta M Zanetti; Massimiliano Salaorno; Giovanni Grasso; Alberto L Audenino
Journal:  Open Med Inform J       Date:  2009-04-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.