Literature DB >> 1448248

Prediction of the small for gestational age infant: which ultrasonic measurement is best?

T C Chang1, S C Robson, R J Boys, J A Spencer.   

Abstract

OBJECTIVE: To determine the most appropriate ultrasonic measurement for the prediction of a small for gestational age (SGA) infant. DATA SOURCES: A literature search of all English language journals over the last 15 years was undertaken. One hundred seventeen articles on the use of morphometric and Doppler ultrasonic measurements in the diagnosis of SGA were reviewed. METHODS OF STUDY SELECTION: Studies were included if antenatal and postnatal criteria for diagnosis were clearly defined and data for SGA and normal fetuses were reported, allowing the construction of a 2 x 2 table. DATA EXTRACTION AND SYNTHESIS: Studies with the same criteria were grouped according to whether the population was high or low risk. The sensitivity, odds ratio (OR), and false-positive rate were calculated for each study; summary statistics were then calculated for each ultrasonic measurement provided the individual sensitivities, ORs, and false-positive rates were not significantly different (P > .01).
CONCLUSIONS: In high-risk subjects, abdominal circumference below the tenth percentile had the highest common sensitivity, and estimated fetal weight below the tenth percentile had the highest common OR. In studies in which morphometric and Doppler ultrasonic measurements were compared in the same subjects, the Doppler ORs tended to be lower than the ORs for morphometric measurements. In low-risk subjects, much lower ORs were found for all ultrasonic measurements. The heterogeneous nature of the studies reviewed may have contributed to the different results within each group.

Entities:  

Mesh:

Year:  1992        PMID: 1448248

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  15 in total

1.  Fetal abdominal protuberance ratio throughout pregnancy.

Authors:  J Morales-Roselló; J Morales-Sanchez
Journal:  Arch Gynecol Obstet       Date:  1996       Impact factor: 2.344

2.  Diagnostic accuracy of fundal height and handheld ultrasound-measured abdominal circumference to screen for fetal growth abnormalities.

Authors:  Adriane F Haragan; Thomas C Hulsey; Angela F Hawk; Roger B Newman; Eugene Y Chang
Journal:  Am J Obstet Gynecol       Date:  2015-03-25       Impact factor: 8.661

3.  Assessment of Antepartum Fetal Growth by Customized "GROW" Curves Versus Noncustomized Growth Curves in Correlation with Neonatal Growth Pattern.

Authors:  Shamim Khandaker
Journal:  J Obstet Gynaecol India       Date:  2014-03-07

Review 4.  Fetal Growth Restriction.

Authors:  Deepti Shrivastava; Ayesha Master
Journal:  J Obstet Gynaecol India       Date:  2019-09-27

5.  Fetal weight normograms for singleton pregnancies in a Jordanian population.

Authors:  Nahla Subhi Al-Bayyari; Adel Taha Abu-Heija
Journal:  Ann Saudi Med       Date:  2010 Mar-Apr       Impact factor: 1.526

6.  Color doppler evaluation of cerebral-umbilical pulsatility ratio and its usefulness in the diagnosis of intrauterine growth retardation and prediction of adverse perinatal outcome.

Authors:  Shahina Bano; Vikas Chaudhary; Sanjay Pande; Vl Mehta; Ak Sharma
Journal:  Indian J Radiol Imaging       Date:  2010-02

7.  Association of third-trimester abdominal circumference with provider-initiated preterm delivery.

Authors:  Leah K Hawkins; William T Schnettler; Anna M Modest; Michele R Hacker; Diana Rodriguez
Journal:  J Matern Fetal Neonatal Med       Date:  2013-11-11

8.  Umbilical vessel wall fatty acids after normal and retarded fetal growth.

Authors:  C V Felton; T C Chang; D Crook; M Marsh; S C Robson; J A Spencer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-01       Impact factor: 5.747

9.  Unconditional and conditional standards for fetal abdominal circumference and estimated fetal weight in an ethnic Chinese population: a birth cohort study.

Authors:  Ying Xu; Ngee Lek; Yin Bun Cheung; Arijit Biswas; Lin Lin Su; Kenneth Y C Kwek; George S H Yeo; Shu-E Soh; Seang-Mei Saw; Peter D Gluckman; Yap-Seng Chong
Journal:  BMC Pregnancy Childbirth       Date:  2015-06-25       Impact factor: 3.007

10.  Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small-for-gestational-age infant in women presenting with reduced symphysis-fundus height.

Authors:  M Griffin; P T Seed; L Webster; J Myers; L MacKillop; N Simpson; D Anumba; A Khalil; M Denbow; A Sau; K Hinshaw; P von Dadelszen; S Benton; J Girling; C W G Redman; L C Chappell; A H Shennan
Journal:  Ultrasound Obstet Gynecol       Date:  2015-07-03       Impact factor: 7.299

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.