Literature DB >> 14339261

SOLUBLE ANTIGEN FLUORESCENT-ANTIBODY TECHNIQUE.

A J TOUSSAINT, R I ANDERSON.   

Abstract

An indirect fluorescent-antibody (FA) procedure employing soluble antigen fixed onto an artificial matrix was developed, and a mechanical means for reading of test results was devised. The method employs two small cellulose acetate paper discs for each test. One disc contains soluble antigen diluted in 1% bovine serum albumin (BSA); the other contains only 1% BSA and serves as a control. After testing by the indirect FA procedure, the results of the tests are read on a fluorometer fitted with a paper chromatogram door. The instrument is set at zero with the control disc as a blank, and the specific fluorescence of the antigen disc is determined. Findings obtained with homologous and heterologous antisera indicated that the method yields excellent results. The soluble antigen fluorescent-antibody technique has definite advantages over the conventional indirect FA procedures. (i) The investigator may objectively select the antigen to be employed. (ii) It is possible to obtain objective mechanical reading of test results rather than the highly subjective readings required by conventional methods. (iii) The system compensates for any nonspecific fluorescence contributed either by the serum (e.g., drugs) or by free fluorescein in the conjugated antiserum.

Entities:  

Keywords:  ANTIGENS; FLUORESCEINS; FLUORESCENT ANTIBODY TECHNIC; HEAT; PHARMACOLOGY; SCHISTOSOMA; SCHISTOSOMIASIS; SERUM ALBUMIN, BOVINE

Mesh:

Substances:

Year:  1965        PMID: 14339261      PMCID: PMC1058296          DOI: 10.1128/am.13.4.552-558.1965

Source DB:  PubMed          Journal:  Appl Microbiol        ISSN: 0003-6919


  10 in total

1.  Relationship of antibody nitrogen to titer obtained in the cercarial antigen slide flocculation test for schistosomiasis.

Authors:  R I ANDERSON
Journal:  Exp Parasitol       Date:  1962-12       Impact factor: 2.011

2.  Serologic diagnosis of Schistosoma mansoni infections. II. Sensitivity of intradermal and serologic tests on individuals with an unequivocal diagnosis of schistosomiasis.

Authors:  R I ANDERSON; D H NAIMARK
Journal:  Am J Trop Med Hyg       Date:  1960-11       Impact factor: 2.345

3.  Precise standardization of reagents for complement fixation.

Authors:  J F KENT; E H FIFE
Journal:  Am J Trop Med Hyg       Date:  1963-01       Impact factor: 2.345

4.  The fluorescent antibody technique applied to titration and identification of antigens in solutions or antisera.

Authors:  F PARONETTO
Journal:  Proc Soc Exp Biol Med       Date:  1963-06

5.  Fluorescent spot test for anti-nuclear antibodies.

Authors:  G FRIOU
Journal:  Arthritis Rheum       Date:  1962-08

6.  Antigenic analysis of Entamoeba histolytica by means of fluorescent antibody. I. Instrumentation for microfluorimetry of stained amebae.

Authors:  M GOLDMAN
Journal:  Exp Parasitol       Date:  1960-02       Impact factor: 2.011

7.  Detection of antibodies by fluorescent-spot technique.

Authors:  H J CRAWFORD; R M WOOD; M H LESSOF
Journal:  Lancet       Date:  1959-12-26       Impact factor: 79.321

8.  Serodiagnosis of schistosomiasis: specificity of the complement-fixation test in other helminthic infections.

Authors:  E F CHAFFEE; E E NIEVES
Journal:  Am J Trop Med Hyg       Date:  1957-07       Impact factor: 2.345

9.  Diagnosis of schistosomiasis by complement-fixation.

Authors:  E F CHAFFEE; P M BAUMAN; J J SHAPILO
Journal:  Am J Trop Med Hyg       Date:  1954-09       Impact factor: 2.345

10.  Evaluation of some laboratory procedures in diagnosing infections with Schistosoma mansoni.

Authors:  L A JACHOWSKI; R I ANDERSON
Journal:  Bull World Health Organ       Date:  1961       Impact factor: 9.408

  10 in total
  7 in total

1.  [Necessary research in the subject of taeniasis-cysticercosis].

Authors: 
Journal:  Bull World Health Organ       Date:  1976       Impact factor: 9.408

2.  Titration of human serum antibodies to Toxoplasma gondii with a simple fluorometric assay.

Authors:  K W Walls; E R Barnhart
Journal:  J Clin Microbiol       Date:  1978-02       Impact factor: 5.948

3.  Evaluation of immunofluorescence with artificial sections of selected antigenicity.

Authors:  P Brandtzaeg
Journal:  Immunology       Date:  1972-01       Impact factor: 7.397

4.  Automated immunofluorescence test for toxoplasmosis.

Authors:  M A Gordon; R A Duncan; L C Kingsley
Journal:  J Clin Microbiol       Date:  1981-02       Impact factor: 5.948

5.  The application of the soluble antigen fluorescent antibody test for the diagnosis of avian influenza.

Authors:  M Al-Attar; K Nielsen; W R Mitchell
Journal:  Can J Comp Med       Date:  1981-04

6.  Immunological properties of Friend virus from mouse spleen obtained by gel filtration.

Authors:  S P Chan; M A Chirigos; W A Hook
Journal:  Appl Microbiol       Date:  1969-01

7.  Soluble antigens for immunofluorescence detection of Histoplasma capsulatum antibodies.

Authors:  W A Hook; E H Fife
Journal:  Appl Microbiol       Date:  1967-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.