The pathology of wear in the Beall model 104 heart valve prosthesis.

M D Silver, G J Wilson.   

Abstract

We examined 13 Beall model 104 prostheses recovered at surgery or autopsy 10 to 84 1/2 months after insertion and observed the pattern of prosthesis wear. We defined wear as "mild" when the disc was notched but neither the metal of the struts was exposed not the cloth seat torn. In "moderate" wear the disc was notched, the Teflon coating of the struts was worn away exposing the underlying metal but the cloth of the set was not torn. The cloth seat was torn in "severe" wear, exposing the metal seat and causing a different pattern of disc erosion. In one case this allowed the disc to tilt into the valve lumen and, later, to escape from its cage. Most of the prostheses studied showed "moderate" or "severe" wear. We believe that some degree of wear is inevitable. Clinical signs and symptoms were not specific but a rough correlation existed between the severity of hemolysis, as indicated by serum LDH levels, and the degree of prosthesis wear. When wear was "severe", the results of cardiac catheterization studies usually mirrored the change, but there were a few exceptions. All patients with the Beall model 104 prosthesis may eventually develop "severe" wear, and we recommend regular reassessment with a view toward prosthesis replacement.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 143353     DOI: 10.1161/01.cir.56.4.617

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  5 in total

1.  THE DAY THE LAST HEART VALVE WAS MADE.

Authors:  Duncan Barr
Journal:  Cardiovasc Dis       Date:  1978-06

2.  Ten-year pathological study of Beall mitral valve prostheses.

Authors:  K S Chang; J Fernandez; S D Cha; S S Yang
Journal:  Thorax       Date:  1982-02       Impact factor: 9.139

3.  Beware of the B(e)all valve: mistaken valve identity, 30-year survival, and valve replacement.

Authors:  On Topaz; Molly S Rutherford; Shannon Mackey-Bojack; Pritam R Polkampally; Allyne Topaz; Andreas Prinz; Szabolcs Szentpetery
Journal:  Tex Heart Inst J       Date:  2010

Review 4.  Bioengineering aspects of heart valve replacement.

Authors:  F J Schoen; J L Titus; G M Lawrie
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

Review 5.  Cardiac prostheses-related hemolytic anemia.

Authors:  Mohamad Alkhouli; Ali Farooq; Ronald S Go; Sudarshan Balla; Chalak Berzingi
Journal:  Clin Cardiol       Date:  2019-05-06       Impact factor: 2.882

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.