Literature DB >> 1430427

Use of fluid attenuated inversion recovery (FLAIR) pulse sequences in MRI of the brain.

J V Hajnal1, D J Bryant, L Kasuboski, P M Pattany, B De Coene, P D Lewis, J M Pennock, A Oatridge, I R Young, G M Bydder.   

Abstract

Fluid attenuated inversion recovery pulse sequences with a long echo time (TE) have been used to image the brain in one volunteer and four patients. The long inversion time used with this sequence suppresses the signal from CSF and the long TE produces very heavy T2 weighting. The marked reduction in flow artefact from CSF and the high T2 weighting enabled anatomical detail to be seen within the brain stem and produced high lesion contrast in areas close to CSF. Lesions were demonstrated with greater conspicuity than with conventional T2-weighted sequences in patients with cerebral infarction, low grade astrocytoma, and diplegia.

Entities:  

Mesh:

Year:  1992        PMID: 1430427     DOI: 10.1097/00004728-199211000-00001

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  67 in total

1.  Intraarterial signal on fluid-attenuated inversion recovery images: a measure of hemodynamic stress?

Authors:  R L Wolf
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

2.  Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging.

Authors:  Hsiu-Mei Wu; David M Yousem; Hsiao-Wen Chung; Wan-Yuo Guo; Cheng-Yen Chang; Cheng-Yu Chen
Journal:  AJNR Am J Neuroradiol       Date:  2002-03       Impact factor: 3.825

Review 3.  Neuroimaging of hemorrhage and vascular defects.

Authors:  Fazeel M Siddiqui; Simon V Bekker; Adnan I Qureshi
Journal:  Neurotherapeutics       Date:  2011-01       Impact factor: 7.620

4.  Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Tatsuya Nakamura; Hisashi Kawai; Hiroshi Fukatsu; Takeo Ishigaki; Tomomi Komada; Katsuya Maruyama; Osamu Takizawa
Journal:  Eur Radiol       Date:  2004-06-19       Impact factor: 5.315

5.  Gradient echo plural contrast imaging--signal model and derived contrasts: T2*, T1, phase, SWI, T1f, FST2*and T2*-SWI.

Authors:  Jie Luo; Bharathi D Jagadeesan; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Neuroimage       Date:  2012-01-28       Impact factor: 6.556

6.  Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

Authors:  Martin Ott; Martin Blaimer; Felix Breuer; David Grodzki; Björn Heismann; Peter Jakob
Journal:  MAGMA       Date:  2015-10-22       Impact factor: 2.310

7.  Neuromarkers of the common angiotensinogen polymorphism in healthy older adults: A comprehensive assessment of white matter integrity and cognition.

Authors:  Lauren E Salminen; Peter R Schofield; Kerrie D Pierce; Yi Zhao; Xi Luo; Youdan Wang; David H Laidlaw; Ryan P Cabeen; Thomas E Conturo; David F Tate; Erbil Akbudak; Elizabeth M Lane; Jodi M Heaps; Jacob D Bolzenius; Laurie M Baker; Lee M Cagle; Robert H Paul
Journal:  Behav Brain Res       Date:  2015-08-28       Impact factor: 3.332

Review 8.  Iron metabolism and its detection through MRI in parkinsonian disorders: a systematic review.

Authors:  Sara Pietracupa; Antonio Martin-Bastida; Paola Piccini
Journal:  Neurol Sci       Date:  2017-09-02       Impact factor: 3.307

Review 9.  Advanced MRI strategies for assessing spinal cord injury.

Authors:  Seth A Smith; James J Pekar; Peter C M van Zijl
Journal:  Handb Clin Neurol       Date:  2012

10.  Evaluation of lateral pterygoid muscles in painful temporomandibular joints by signal intensity on fluid-attenuated inversion recovery images.

Authors:  Migiwa Kuroda; Mika Otonari-Yamamoto; Kazuyuki Araki
Journal:  Oral Radiol       Date:  2017-03-27       Impact factor: 1.852

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.