Literature DB >> 1429105

Computer systems and mechanical tools for stereotactically guided conformation therapy with linear accelerators.

W Schlegel1, O Pastyr, T Bortfeld, G Becker, L Schad, G Gademann, W J Lorenz.   

Abstract

An integrated system for fractionated, stereotactically guided conformation radiotherapy has been developed. The system components are a stereotactic fixation system that can be used each treatment day, a localization, and positioning unit that can be used during x-ray computer tomography, magnetic resonance imaging, positron emission tomography, and radiographical examinations as well as for treatment. Conformal precision radiotherapy is planned with a new three-dimensional treatment planning system (Voxel-Plan-Heidelberg) which comprises, among others options, a three-dimensional image correlation procedure as well as routines for the calculation of coplanar and non-coplanar irradiations with irregularly shaped fields. Two different multi-leaf collimators have been designed for precision radiotherapy in the head and neck region. A manual multi-leaf collimator is used for irradiations with stationary beams or for moving beam treatments with invariable irregularly shaped fields. This collimator system is now being used for patient treatments. The design of a computer controlled multi-leaf collimator unit for multiple fixed field irradiation techniques is discussed. All system components are aimed at conforming dose distributions for fractionated radiotherapy treatments to the target to improve sparing of adjacent normal tissues, and at achieving a sufficient geometrical accuracy in the dose application.

Entities:  

Mesh:

Year:  1992        PMID: 1429105     DOI: 10.1016/0360-3016(92)90729-2

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  15 in total

1.  Dosimetric integration of daily mega-voltage cone-beam CT for image-guided intensity-modulated radiotherapy.

Authors:  A Zabel-du Bois; S Nill; S Ulrich; U Oelfke; B Rhein; P Haering; S Milker-Zabel; A Schwahofer
Journal:  Strahlenther Onkol       Date:  2012-01-05       Impact factor: 3.621

2.  Interventional telemedicine for noninvasive neuroradiosurgery: remote-site high-performance computing, mathematical optimization, and virtual scenario simulation.

Authors:  R von Hanwehr; G F Popescu; H E Taylor; K H Winkler; C E Swenberg
Journal:  J Med Syst       Date:  1995-06       Impact factor: 4.460

3.  Using an artificial neural network to define the planning target volume in radiotherapy.

Authors:  N Kaspari; B Michaelis; G Gademann
Journal:  J Med Syst       Date:  1997-12       Impact factor: 4.460

4.  Follow-up gliomas after radiotherapy: 1H MR spectroscopic imaging for increasing diagnostic accuracy.

Authors:  Matthias Philipp Lichy; Christian Plathow; Daniela Schulz-Ertner; Hans-Ulrich Kauczor; Heinz-Peter Schlemmer
Journal:  Neuroradiology       Date:  2005-09-02       Impact factor: 2.804

5.  Comparison of Safety Margin Generation Concepts in Image Guided Radiotherapy to Account for Daily Head and Neck Pose Variations.

Authors:  Markus Stoll; Eva Maria Stoiber; Sarah Grimm; Jürgen Debus; Rolf Bendl; Kristina Giske
Journal:  PLoS One       Date:  2016-12-29       Impact factor: 3.240

Review 6.  [Stereotactic one-time irradiation (radiosurgery). The methods, indications and results].

Authors:  J Debus; A Pirzkall; W Schlegel; M Wannenmacher
Journal:  Strahlenther Onkol       Date:  1999-02       Impact factor: 3.621

7.  [Principles of radiation therapy for malignant tumors of the orbit and the periorbital area].

Authors:  T Kuhnt; M Janich
Journal:  HNO       Date:  2010-01       Impact factor: 1.284

8.  Results of three-dimensional stereotactically-guided radiotherapy in recurrent medulloblastoma.

Authors:  Stefanie Milker-Zabel; Angelika Zabel; Christoph Thilmann; Ivan Zuna; Angelika Hoess; Michael Wannenmacher; Jürgen Debus
Journal:  J Neurooncol       Date:  2002-12       Impact factor: 4.130

9.  The role of MRI in patients with astrocytoma WHO II treated with fractionated stereotactic radiotherapy.

Authors:  Christian Plathow; Matthias Philipp Lichy; Peter Bachert; Ivan Zuna; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2003-11-11       Impact factor: 5.315

10.  Fractionated stereotactic radiation therapy in the management of primary optic nerve sheath meningiomas.

Authors:  Stefanie Milker-Zabel; Peter Huber; Wolfgang Schlegel; Jürgen Debus; Angelika Zabel-du Bois
Journal:  J Neurooncol       Date:  2009-04-01       Impact factor: 4.130

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.