Literature DB >> 1427137

Use of the argon laser to close filtering bleb leaks.

H L Hennis1, W C Stewart.   

Abstract

We attempted to seal 15 consecutive filtering bleb leaks in 11 patients using argon laser energy. Eight leaks were at the conjunctival-corneal interface associated with a fornix-based flap, 4 leaks resulted from suture scissoring of the conjunctiva, and 3 leaks were button-holes in the conjunctiva. Thirteen leaks occurred within 2 weeks after filtering surgery, while 2 were of late onset. Argon laser parameters used were a 500-microns spot size, 0.1-s time interval, and between 500 and 1800 mW of power. Thirteen leaks were sealed after one or two laser sessions, while 2 leaks required other treatment modalities. Complications included conjunctival fenestration and transient corneal stromal opacities. This study suggests that the argon laser can be used to seal filtering bleb leaks in many patients following filtering surgery.

Entities:  

Mesh:

Year:  1992        PMID: 1427137     DOI: 10.1007/bf00181775

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  11 in total

1.  Use of a symblepharon ring for treatment of over-filtration and leaking blebs after glaucoma filtration surgery.

Authors:  R A Hill; A Aminlari; J W Sassani; M Michalski
Journal:  Ophthalmic Surg       Date:  1990-10

2.  Use of the Megasoft Bandage Lens for treatment of complications after trabeculectomy.

Authors:  M D Blok; J H Kok; C van Mil; E L Greve; A Kijlstra
Journal:  Am J Ophthalmol       Date:  1990-09-15       Impact factor: 5.258

3.  Repair of a leaking bleb with fibrin glue.

Authors:  K Kajiwara
Journal:  Am J Ophthalmol       Date:  1990-05-15       Impact factor: 5.258

4.  Use of a collagen shield to treat a glaucoma filter bleb leak.

Authors:  S Fourman; L Wiley
Journal:  Am J Ophthalmol       Date:  1989-06-15       Impact factor: 5.258

5.  Management of large filtering blebs with the argon laser.

Authors:  A J Fink; J W Boys-Smith; R Brear
Journal:  Am J Ophthalmol       Date:  1986-06-15       Impact factor: 5.258

6.  Repair of an inadvertent buttonhole or leaking filtering bleb.

Authors:  G J Petursson; F T Fraunfelder
Journal:  Arch Ophthalmol       Date:  1979-05

7.  Use of isobutyl-2-cyanoacrylate tissue adhesive in the repair of conjunctival fistula in filtering procedures for glaucoma.

Authors:  K J Awan; P G Spaeth
Journal:  Ann Ophthalmol       Date:  1974-08

8.  Treatment of hypotony following filtering surgery for glaucoma.

Authors:  H S Sugar
Journal:  Am J Ophthalmol       Date:  1971-05       Impact factor: 5.258

Review 9.  Ciliochoroidal detachment.

Authors:  R F Brubaker; J E Pederson
Journal:  Surv Ophthalmol       Date:  1983 Mar-Apr       Impact factor: 6.048

10.  Management of leaking filtration blebs.

Authors:  C P Tomlinson; C D Belcher; P D Smith; R J Simmons
Journal:  Ann Ophthalmol       Date:  1987-11
View more
  5 in total

1.  Argon laser-assisted treatment of benign eyelid lesions.

Authors:  Şafak Korkmaz; Feyzahan Ekici; Sabahattin Sül
Journal:  Lasers Med Sci       Date:  2015-01-07       Impact factor: 3.161

2.  Outcomes of bleb excision and conjunctival advancement for leaking or hypotonous eyes after glaucoma filtering surgery.

Authors:  D P Tannenbaum; D Hoffman; M J Greaney; J Caprioli
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

3.  Bleb Revision using Reversed Scleral Flap and Pedical Conjunctival Graft.

Authors:  Sourabh Sharma; Dhaval Patel; Reetika Sharma; Tanuj Dada
Journal:  J Curr Glaucoma Pract       Date:  2012-08-16

4.  Polyethylene Glycol-Based Synthetic Hydrogel Sealant for Filtration Bleb Leaks: An In Vivo and Histologic Study.

Authors:  Tatsuo Nagata; Yukinori Harada; Mikki Arai; Tatsuo Hirose; Hiroyuki Kondo
Journal:  Transl Vis Sci Technol       Date:  2020-05-22       Impact factor: 3.283

5.  Modified argon laser therapy for benign tumor of the eyelid.

Authors:  Jisang Han; Shin-Hyo Lee; Chul Young Choi; Ramin Khoramnia; Jaemin Kim; Hyun Jin Shin
Journal:  BMC Ophthalmol       Date:  2022-09-24       Impact factor: 2.086

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.