Literature DB >> 1414947

Automated, on-line quantification of left ventricular dimensions and function by echocardiography with backscatter imaging and lateral gain compensation.

J E Pérez1, S C Klein, D M Prater, C E Fraser, H Cardona, A D Waggoner, M R Holland, J G Miller, B E Sobel.   

Abstract

To provide on-line quantification of left ventricular cavity dimensions and function by echocardiography 60 control subjects and 10 patients with cardiac dysfunction were studied. A novel, ultrasound imaging system was used which was developed to detect and track, in real time, ventricular endocardial blood boundaries based on quantitative assessment of acoustic properties of tissue. In addition, lateral gain compensation, a robust and novel image enhancement procedure, was used to provide instantaneous measurement and display of cavity areas and functional indexes on a beat-by-beat basis within regions of interest drawn around the blood pool cavity. In control subjects, short-axis end-diastolic area averaged 13.1 +/- 3.7 cm2 (SD), end-systolic area 5.9 +/- 2.7 cm2, and fractional area change 55.6 +/- 11.2%. Apical views yielded corresponding values of 23.8 +/- 4.5 cm2, 15.5 +/- 3.4 cm2 and 34.7 +/- 7.8%. Instantaneous peak rate of cavity area change approximated 50 cm2/s in systole and 60 cm2/s in diastole in each view. Serial measurements of area and functional index were reproducible over intervals of 2 to 3 weeks. Patients with dilated ventricles exhibited average apical view area values of 49.1 +/- 6.1 cm2 and 43.1 +/- 4.9 cm2 in diastole and systole with a fractional area change of 12.2 +/- 3.0%. Thus, results with on-line echocardiographic backscatter imaging-assisted automated edge detection are reproducible and capable of delineating cardiac dysfunction conveniently, promptly and serially at the bedside.

Entities:  

Mesh:

Year:  1992        PMID: 1414947     DOI: 10.1016/0002-9149(92)90056-5

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

Review 1.  Developments in cardiovascular ultrasound. Part 3: Cardiac applications.

Authors:  C M Moran; W N McDicken; P R Hoskins; P J Fish
Journal:  Med Biol Eng Comput       Date:  1998-09       Impact factor: 2.602

2.  Analysis of cardiac left-ventricular volume based on time warping averaging.

Authors:  E G Caiani; A Porta; G Baselli; M Turiel; S Muzzupappa; M Pagani; A Malliani; S Cerutti
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

3.  Aging change of left ventricular function in children evaluated by acoustic quantification method.

Authors:  Yuko Sato; Asami Maruyama; Ko Ichihashi
Journal:  J Echocardiogr       Date:  2011-02-24

4.  Impact of presence of abnormal wall motion on echocardiographic determination of left ventricular function with automated boundary detection technique: re-evaluation.

Authors:  G C Zhang; K Nakamura; T Tsukada; S Nakatani; M Uematsu; N Tanaka; Y Masuda; Y Yasumura; K Miyatake; M Yamagishi
Journal:  Int J Card Imaging       Date:  1998-08

5.  Echocardiography, pulmonary artery catheterization, and radionuclide cineangiography in septic shock.

Authors:  R E Cunnion; C Natanson
Journal:  Intensive Care Med       Date:  1994-11       Impact factor: 17.440

6.  Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data.

Authors:  J Gorcsan; W A Mandarino; L G Deneault; S Morita; A Kawai; B P Griffith; R L Kormos
Journal:  Int J Card Imaging       Date:  1994-06

7.  Dynamic on-line quantification of biventricular function with acoustic quantification (AQ). Validation, reproducibility and normal values of a new echocardiographic approach.

Authors:  B Hausmann; S Muurling; R Simon
Journal:  Int J Card Imaging       Date:  1997-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.