Literature DB >> 1397457

Digital subtraction radiography in artificial recurrent caries detection.

P V Nummikoski1, T S Martinez, S R Matteson, W D McDavid, S B Dove.   

Abstract

The diagnostic accuracy of digital subtraction radiography in detection of artificial recurrent caries lesions was assessed in this project. The use of digital subtraction radiography has been shown to markedly increase the accuracy of the detection of destruction in the periodontal bone, but the method has not been evaluated in secondary caries detection. Defects of three different sizes, simulating recurrent caries, were sequentially prepared in the interproximal cavity preparation margins of 28 teeth. Two composite restorative materials with different radiographic densities were used as posterior restorations, and a radiograph was obtained of each defect size and restorative material. The radiographs were digitized and subtracted from the reference images, and the conventional radiographs and the subtraction images were evaluated by seven observers. The data were analysed with ROC statistics. Subtraction radiography was found to be superior to conventional radiography in recurrent caries detection, mainly by reducing the false-positive diagnoses. The radiopacity of the restorative material had a significant effect on accuracy with conventional but not with subtraction radiography.

Entities:  

Mesh:

Year:  1992        PMID: 1397457     DOI: 10.1259/dmfr.21.2.1397457

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  5 in total

1.  Diagnostic accuracy of proximal enamel subsurface demineralization and its relationship with calcium loss and lesion depth.

Authors:  E Onem; B G Baksi; B H Sen; O Sögüt; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  Assessment of Mandibular Distraction Regenerate Using Ultrasonography and Cone Beam Computed Tomography: A Clinical Study.

Authors:  Jitender Dabas; Sujata Mohanty; Zainab Chaudhary; Amita Rani
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2015-09-24

3.  Development of a novel digital subtraction technique for detecting subtle changes in jawbone density.

Authors:  Frank Du Tré; Reinhilde Jacobs; Sean Styven; Daniel van Steenberghe
Journal:  Clin Oral Investig       Date:  2006-06-13       Impact factor: 3.573

4.  Cone Beam Computed Tomography- An Effective Tool in Detecting Caries Under Fixed Dental Prostheses.

Authors:  Priyanka Ramesh Vedpathak; Shailesh Madhukar Gondivkar; Ajay Ramesh Bhoosreddy; Karan Rajendra Shah; Gaurav Ravishankar Verma; Gayatri Praveen Mehrotra; Ashwini Chandrakant Nerkar
Journal:  J Clin Diagn Res       Date:  2016-08-01

5.  A comparative study of the physicochemical properties of hesperidin, MTA-Angelus and calcium hydroxide as pulp capping materials.

Authors:  Ebtesam O Abo El-Mal; Ashraf M Abu-Seida; Salma H El Ashry
Journal:  Saudi Dent J       Date:  2018-09-15
  5 in total