This study demonstrates the ability of an automated blood gas analyzer (Radiometer ABL 330) operated at atmospheric pressure to measure the arterial oxygen tension (PaO2) of ten healthy volunteers exposed to hyperbaric oxygen (HBO2) up to 3.0 atmospheres absolute. Arterial blood samples were aspirated from subjects compressed in a single-person hyperbaric chamber and were analyzed immediately in the blood gas analyzer. The subjects' values for PaO2 correlated with the calculated alveolar O2 tension (PAO2) (measured PaO2 = 0.827 x PAO2-15.1) (r2 = 0.97). Tonometric experiments indicated a difference between saline and blood PO2 measurements. We therefore derived a correction factor for blood measurements (corrected PaO2 = 0.908 x PAO2-52.4) (r2 = 0.98). These results compared favorably with PaO2 measurements made with blood gas analyzers calibrated inside walk-in hyperbaric chambers. We conclude that the PaO2 of normal subjects exposed to HBO2 can be measured accurately at atmospheric pressure with this automated blood gas analyzer. Prior to this study, hyperbaric PaO2 measurements could only be performed within walk-in chambers. Our observations generalize the normobaric measurement of hyperbaric PaO2 to patients treated in single-person and walk-in chambers.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1395764     DOI: 10.1378/chest.102.4.1175

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  9 in total

Review 1.  Role of hyperoxic treatment in cancer.

Authors:  Sei W Kim; In K Kim; Sang H Lee
Journal:  Exp Biol Med (Maywood)       Date:  2020-04-23

2.  Hyperbaric hyperoxia reduces exercising forearm blood flow in humans.

Authors:  Darren P Casey; Michael J Joyner; Paul L Claus; Timothy B Curry
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-03-18       Impact factor: 4.733

3.  Carotid body chemosensitivity at 1.6 ATA breathing air versus 100% oxygen.

Authors:  Hayden W Hess; David Hostler; Brian M Clemency; Blair D Johnson
Journal:  J Appl Physiol (1985)       Date:  2020-06-25

Review 4.  Monoplace chamber treatment of decompression illness: Review and commentary.

Authors:  Richard Clarke
Journal:  Diving Hyperb Med       Date:  2020-09-30       Impact factor: 0.887

5.  MRI of cerebral blood flow under hyperbaric conditions in rats.

Authors:  Damon P Cardenas; Eric R Muir; Timothy Q Duong
Journal:  NMR Biomed       Date:  2016-05-18       Impact factor: 4.044

6.  Vasoconstrictor responsiveness during hyperbaric hyperoxia in contracting human muscle.

Authors:  Darren P Casey; Michael J Joyner; Paul L Claus; Timothy B Curry
Journal:  J Appl Physiol (1985)       Date:  2012-11-15

Review 7.  Evaluation and management of decompression illness--an intensivist's perspective.

Authors:  Kay Tetzlaff; Erik S Shank; Claus M Muth
Journal:  Intensive Care Med       Date:  2003-11-05       Impact factor: 17.440

8.  MRI of brain tissue oxygen tension under hyperbaric conditions.

Authors:  Eric R Muir; Damon P Cardenas; Timothy Q Duong
Journal:  Neuroimage       Date:  2016-03-24       Impact factor: 6.556

9.  MRI under hyperbaric air and oxygen: effects on local magnetic field and relaxation times.

Authors:  Eric R Muir; Damon Cardenas; Shiliang Huang; John Roby; Guang Li; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2013-11-14       Impact factor: 4.668

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.