Literature DB >> 1395758

Accuracy of respiratory inductive plethysmography during wakefulness and sleep in patients with obstructive sleep apnea.

J P Cantineau1, P Escourrou, R Sartene, C Gaultier, M Goldman.   

Abstract

To assess the accuracy of the respiratory inductive plethysmograph (RIP) during sleep in obese patients with obstructive sleep apnea (OSA), we monitored 13 patients with OSA during wakefulness and nocturnal sleep with simultaneous measurements of tidal volume from RIP and integrated airflow. Patients wore a tightly fitting face mask with pneumotachograph during wakefulness and sleep. Calibrations were performed during wakefulness prior to sleep and compared with subsequent wakeful calibrations at the end of the study. Patients maintained the same posture during sleep (supine, 11; lateral, two) as during calibrations. There were no significant differences in calibrations before sleep and after awakening. The mean error in 13 patients undergoing RIP measurements of tidal volume during wakefulness was -0.7 +/- 3.4 percent while that during sleep was 2.1 +/- 14.9 percent (p < 0.001). The standard deviation (SD) of the differences between individual breaths measured by RIP and integrated airflow was 9.8 +/- 5.5 percent during wakefulness and 25.5 +/- 18.6 percent during sleep (p < 0.001). During both wakefulness and sleep, errors in RIP tidal volume were not significantly correlated with body mass index. In 12 patients with at least 10 percent time in each of stages 1 and 2 sleep, SD was greater in stage 2 sleep compared with wakefulness and stage 1 (p < 0.001). In three patients who manifested all stages of sleep, SD was greater in REM sleep than in wakefulness and all stages of non-REM sleep (p < 0.001). In three patients who manifested all stages of sleep, SD was greater in REM sleep than in wakefulness and all stages of non REM sleep (p < 0.001). This was associated with paradoxic motion of the rib cage in two patients during REM. We conclude that, despite increased errors in individual breath measurements during sleep, more marked during stages 2 and REM sleep, RIP is clinically useful to measure ventilation quantitatively in obese patients with sleep apnea. The criterion of a decrease of 50 percent in tidal volume assessed by RIP is appropriate to define hypopneas in such patients.

Entities:  

Mesh:

Year:  1992        PMID: 1395758     DOI: 10.1378/chest.102.4.1145

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  11 in total

Review 1.  Sleep . 3: Clinical presentation and diagnosis of the obstructive sleep apnoea hypopnoea syndrome.

Authors:  D Schlosshan; M W Elliott
Journal:  Thorax       Date:  2004-04       Impact factor: 9.139

2.  Validation of a polyvinylidene fluoride impedance sensor for respiratory event classification during polysomnography.

Authors:  Brian B Koo; Colin Drummond; Susan Surovec; Nathan Johnson; Stephanie A Marvin; Susan Redline
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

Review 3.  Diagnostic issues in pediatric obstructive sleep apnea.

Authors:  Hiren Muzumdar; Raanan Arens
Journal:  Proc Am Thorac Soc       Date:  2008-02-15

4.  Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography.

Authors:  Wai Leung Ambrose Lo; Dong Feng Huang
Journal:  J Clin Monit Comput       Date:  2016-06-11       Impact factor: 2.502

5.  Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine.

Authors:  Richard B Berry; Rohit Budhiraja; Daniel J Gottlieb; David Gozal; Conrad Iber; Vishesh K Kapur; Carole L Marcus; Reena Mehra; Sairam Parthasarathy; Stuart F Quan; Susan Redline; Kingman P Strohl; Sally L Davidson Ward; Michelle M Tangredi
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

6.  Respiratory rate detection algorithm based on RGB-D camera: theoretical background and experimental results.

Authors:  Flavia Benetazzo; Alessandro Freddi; Andrea Monteriù; Sauro Longhi
Journal:  Healthc Technol Lett       Date:  2014-09-29

7.  Nocturnal thoracoabdominal asynchrony in house dust mite-sensitive nonhuman primates.

Authors:  Xiaojia Wang; Shaun Reece; Stephen Olmstead; Robert L Wardle; Michael R Van Scott
Journal:  J Asthma Allergy       Date:  2010-07-28

8.  Evaluation of an ambulatory system for the quantification of cough frequency in patients with chronic obstructive pulmonary disease.

Authors:  Michael A Coyle; Desmond B Keenan; Linda S Henderson; Michael L Watkins; Brett K Haumann; David W Mayleben; Michael G Wilson
Journal:  Cough       Date:  2005-08-04

9.  Sleep continuity: a new metric to quantify disrupted hypnograms in non-sedated intensive care unit patients.

Authors:  Xavier Drouot; Agathe Bridoux; Arnaud W Thille; Ferran Roche-Campo; Ana Cordoba-Izquierdo; Sandrine Katsahian; Laurent Brochard; Marie-Pia d'Ortho
Journal:  Crit Care       Date:  2014-11-25       Impact factor: 9.097

10.  Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems.

Authors:  Zhengbo Zhang; Jiewen Zheng; Hao Wu; Weidong Wang; Buqing Wang; Hongyun Liu
Journal:  Sensors (Basel)       Date:  2012-09-27       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.