Distribution and size of particles after dynamic angioplasty in cadaveric arteries with the Kensey catheter system: a comparison with clinical experience.

D Moellmann1, F P Kuhn, D Bömer.   

Abstract

The distribution and size of atheromatous debris after angioplasty with the Kensey catheter was determined after recanalization of 18 segments of human cadaveric superficial femoral arteries (SFA). The debris produced was studied cytologically and measured semiquantitatively. Nearly 80% of all particles ranged from 5 to 15 microns, approximately the size of red blood cells. More than 20% of all particles exceeded this size and 2% were larger than 100 microns. The use of the Kensey catheter dynamic angioplasty system in the lower extremities contains the risk of embolic complications because more than 20% of all particles are larger than human blood cells. Seven patients with occlusion and 3 with stenoses of the SFA were treated with the Kensey catheter system. Recanalization was successful in all and in 1 case, small emboli in the anterior tibial artery were observed. There was a 50% restenosis/reocclusion rate between 2 weeks and 10 months.

Entities:  

Mesh:

Year:  1992        PMID: 1394354     DOI: 10.1007/bf02733922

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  7 in total

1.  New reperfusion devices: the Kensey catheter, the atherolytic reperfusion wire device, and the transluminal extraction catheter.

Authors:  M H Wholey; C R Jarmolowski
Journal:  Radiology       Date:  1989-09       Impact factor: 11.105

2.  [Clinical experience with the Kensey catheter system--complications and results].

Authors:  V H Schild; G Zocholl; H Kopp; W Schmiedt; K Schunk; U Hake; H Jakob; M Thelen
Journal:  Rofo       Date:  1990-02

3.  Recanalization of obstructed arteries with a flexible, rotating tip catheter.

Authors:  K R Kensey; J E Nash; C Abrahams; C K Zarins
Journal:  Radiology       Date:  1987-11       Impact factor: 11.105

4.  First own results with dynamic angioplasty with the Kensey-catheter.

Authors:  E Zeitler; K Kensey
Journal:  Ann Radiol (Paris)       Date:  1988

5.  Functional properties of the Kensey arterial recanalization catheter. In vitro investigations.

Authors:  T Schmitz-Rode; R W Günther
Journal:  Invest Radiol       Date:  1990-06       Impact factor: 6.016

6.  Atheroablation with the Kensey catheter: a pathologic study.

Authors:  C C Coleman; I P Posalaky; J D Robinson; W D Payne; Z A Vlodaver; K Amplatz
Journal:  Radiology       Date:  1989-02       Impact factor: 11.105

7.  Recanalization of total arterial occlusions with the Kensey dynamic angioplasty catheter.

Authors:  M H Wholey; J A Smith; P Godlewski; M Nagurka
Journal:  Radiology       Date:  1989-07       Impact factor: 11.105

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.