Chlamydia trachomatis antigen detection by Chlamydiazyme combined with Chlamydia Blocking Reagent verification.

B Zeeberg1, I Thelin, C Schalén.   

Abstract

Several options exist for the detection of chlamydial infection in a routine laboratory setting. Enzyme immuno assay (EIA) technology offers rapid turn around of results and is less technically demanding than chlamydial cell culture. In addition, recently introduced EIA confirmatory reagents have the potential to improve the accuracy of EIA detection. We have evaluated one such confirmatory reagent (Chlamydia Blocking Reagent, Abbott Laboratories) to determine the accuracy of the Chlamydiazyme EIA with special regard to interpretation of low absorbance values. An initial series of 192 male urethral specimens showed that use of a lowered cut off level (absorbance value 0.05) compared with that recommended by the manufacturer increased sensitivity of the EIA from 0.73 to 0.83, thus motivating studies on this interpretative modification. Of 1101 EIA reactive specimens, 65% were determined to be chlamydia positive by the Chlamydia Blocking Reagent. The proportion of female cervical specimens that did not confirm positive was elevated compared with male urethral specimens, 43% vs. 5.7% respectively. In samples yielding absorbance from the recommended cut off level to 0.05 (approximately 50% below), the corresponding figures were 78% and 14% respectively. In 85 selected EIA reactive samples, examination by a direct immunofluorescence staining assay (DFA) (MicroTrak, Syva Inc.) revealed elementary bodies in 85% of 67 blocking test positive and in 24% of 18 blocking test negative samples. The possibility that Gram-negative bacteria were responsible for unconfirmed EIA reactive specimens was investigated using bacterial suspensions. While EIA reactivity was noted with several strains for Gram-negative bacteria, both the blocking reagent and DFA correctly verified the absence of chlamydial antigen.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1391063     DOI: 10.1177/095646249200300510

Source DB:  PubMed          Journal:  Int J STD AIDS        ISSN: 0956-4624            Impact factor:   1.359


  3 in total

1.  Lowering the cut off value of an automated chlamydia enzyme immunoassay and confirmation by PCR and direct immunofluorescent antibody test.

Authors:  C Y Tong; C Donnelly; N Hood
Journal:  J Clin Pathol       Date:  1997-08       Impact factor: 3.411

Review 2.  Current methods of laboratory diagnosis of Chlamydia trachomatis infections.

Authors:  C M Black
Journal:  Clin Microbiol Rev       Date:  1997-01       Impact factor: 26.132

3.  Use of PCR and direct immunofluorescence microscopy for confirmation of results obtained by Syva MicroTrak Chlamydia enzyme immunoassay.

Authors:  L Ostergaard; J K Møller
Journal:  J Clin Microbiol       Date:  1995-10       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.