Literature DB >> 1388963

The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease.

W J Bos1, B P Imholz, J van Goudoever, K H Wesseling, G A van Montfrans.   

Abstract

In conditions of compromised peripheral circulation, the measurement of noninvasive continuous finger blood pressure with the Finapres device may show reduced accuracy. We therefore compared Finapres blood pressure (FINAP) with intrabrachial blood pressure (IAP) responses to the Valsalva maneuver and arising in 12 patients in whom the peripheral circulation was expected to be compromised due to the combination of therapy-resistant hypertension and vascular disease. During a 30 sec control period the FINAP--IAP differences were -15.7 +/- 18.8 mm Hg (mean +/- SD) for systolic, -20.1 +/- 15.7 mm Hg for mean, and -13.5 +/- 15.7 mm Hg for diastolic pressure. During the Valsalva maneuver and prolonged standing Finapres reproduced the essential characteristics of the changes in IAP in all patients. However, in individual patients, the magnitude of the intraarterial blood pressure response was sometimes over- or underestimated by Finapres. Nevertheless, the group averaged blood pressure, in particular mean and diastolic pressure, response to cardiovascular stimuli, was well reproduced by Finapres. In conclusion, as expected physiologically, individual Finapres measurements in patients with vascular disease do not always equal the intrabrachial pressure and should thus be evaluated with care. However, the Finapres device can be used with sufficient confidence to study the group averaged responses to cardiovascular stimuli in these patients.

Entities:  

Mesh:

Year:  1992        PMID: 1388963     DOI: 10.1093/ajh/5.8.529

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  16 in total

1.  Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method.

Authors:  E A López-Beltrán; P L Blackshear; S M Finkelstein; J N Cohn
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

2.  Passive leg movement in chronic obstructive pulmonary disease: evidence of locomotor muscle vascular dysfunction.

Authors:  Stephen J Ives; Gwenael Layec; Corey R Hart; Joel D Trinity; Jayson R Gifford; Ryan S Garten; Melissa A H Witman; Jacob R Sorensen; Russell S Richardson
Journal:  J Appl Physiol (1985)       Date:  2020-04-23

3.  Development of noninvasive measurement of peripheral circulation and its medical application.

Authors:  H Nakamura
Journal:  Environ Health Prev Med       Date:  1997-04       Impact factor: 3.674

4.  Reliability of blood pressure determination with the Finapres with altered physiological states or pharmacodynamic conditions.

Authors:  D McAuley; B Silke; S Farrell
Journal:  Clin Auton Res       Date:  1997-08       Impact factor: 4.435

5.  Estimation of beat-to-beat changes in stroke volume from arterial pressure: a comparison of two pressure wave analysis techniques during head-up tilt testing in young, healthy men.

Authors:  W T Jellema; B P Imholz; H Oosting; K H Wesseling; J J van Lieshout
Journal:  Clin Auton Res       Date:  1999-08       Impact factor: 4.435

6.  The use of the CR-10 scale to allow self-regulation of isometric exercise intensity in pre-hypertensive and hypertensive participants.

Authors:  Niamh M Morrin; Mark R Stone; Ian L Swaine; Keiran J Henderson
Journal:  Eur J Appl Physiol       Date:  2017-12-06       Impact factor: 3.078

7.  Noninvasive detection of sympathetic neurocirculatory failure.

Authors:  D S Goldstein; C Tack
Journal:  Clin Auton Res       Date:  2000-10       Impact factor: 4.435

8.  Group III/IV muscle afferents impair limb blood in patients with chronic heart failure.

Authors:  Markus Amann; Massimo Venturelli; Stephen J Ives; David E Morgan; Benjamin Gmelch; Melissa A H Witman; H Jonathan Groot; D Walter Wray; Josef Stehlik; Russell S Richardson
Journal:  Int J Cardiol       Date:  2014-04-21       Impact factor: 4.164

9.  Non-invasive estimation of cardiac output in critical care patients.

Authors:  U M Gerhardt; C Schöller; D Böcker; H Hohage
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

10.  A differing role of oxidative stress in the regulation of central and peripheral hemodynamics during exercise in heart failure.

Authors:  Melissa A H Witman; John McDaniel; Anette S Fjeldstad; Stephen J Ives; Jia Zhao; Jose N Nativi; Josef Stehlik; D Walter Wray; Russell S Richardson
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-09-07       Impact factor: 4.733

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.