Literature DB >> 1388326

Measurement of volumetric coronary blood flow with a Doppler catheter: validation in an animal model.

K Sudhir1, V K Hargrave, E L Johnson, G Aldea, H Mori, T A Ports, P G Yock.   

Abstract

Although Doppler catheter recordings are used to determine coronary flow velocity, their accuracy in the estimation of volumetric blood flow has not been validated. To address this issue, Doppler-derived coronary flow was measured in a canine model and compared with that obtained by means of an electromagnetic flowmeter. A carotid artery-to-circumflex coronary artery shunt was created in six dogs with tubing that incorporated an inline electromagnetic flow device. The circumflex artery was occlusively cannulated by means of a rigid metal stent of known internal diameter, which was placed 2 cm into the vessel, and flow was measured in the stent region by means of a 3F Doppler catheter. Analysis of Doppler shift signals was performed by means of a zero-crossing detector (ZCD) and an off-line fast-Fourier transformation (FFT) system. Flow derived from peak FFT velocities corresponded closely to electromagnetic flow (slope 1.09, r = 0.93), whereas mean FFT and ZCD velocities underestimated electromagnetic flow (with slopes of 0.47 and 0.46, respectively) despite a close correlation (r = 0.92, 0.94). Thus FFT analysis of the Doppler signal with determination of peak velocity gives the most accurate representation of flow, whereas measurements based on ZCD mean velocities may significantly underestimate coronary flow.

Entities:  

Mesh:

Year:  1992        PMID: 1388326     DOI: 10.1016/0002-8703(92)90966-y

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Hemodynamic evaluation of saphenous vein coronary artery bypass grafts: relative merits of Doppler flow velocity and SPECT perfusion imaging.

Authors:  Liesbeth P Salm; Jeroen J Bax; J Wouter Jukema; Susan E Langerak; Hubert W Vliegen; Paul Steendijk; Hildo J Lamb; Albert de Roos; Ernst E van der Wall
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

Review 2.  Developments in cardiovascular ultrasound. Part 2: Arterial applications.

Authors:  P R Hoskins; P J Fish; W N McDicken; C Moran
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

Review 3.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

Review 4.  New technology in echocardiography I: Doppler techniques.

Authors:  W N McDicken; P R Hoskins; C M Moran; G R Sutherland
Journal:  Heart       Date:  1996-06       Impact factor: 5.994

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.